Cited by 7Power Quality and HarmonicsOptimal Power Flow DistributionMicrogrid Control and Optimization

Application of low voltage statcom to correct voltage issues caused by inverter energy systems

Condon, Dean, McPhail, Don, Ingram, David·2016·2016 Australasian Universities Power Engineering Conference (AUPEC)

Abstract

Electricity distributors in Australia are experiencing high penetration of small scale distributed generation, such as solar photovoltaic systems, particularly on houses connected to the low voltage network. Distributed generation is challenging the traditional operating paradigm and can result in occurrences of voltage rising, or even exceeding, statutory limits. This results in the inverter energy systems continuously disconnecting and being unable to generate. This paper presents the results of Ergon Energy's investigation into the application of low voltage static compensators through a desktop study, modelling, laboratory testing, and field trials.

Integrity signals

Registry

Crossref · 10.1109/aupec.2016.7749332

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A combination of 5 kVAr single-phase and 20 kVAr three-phase STATCOM systems was applied in LV feeders in trials by an Australian DNSP.

    “Reference [70] summarizes the findings from trials by an Australian DNSP, where a combination of 5 kVAr single-phase and 20 kVAr three-phase systems was applied in LV feeders.”

Cited by

Sorted by citations

Authors
Condon, D., McPhail, D., & Ingram, D.
Affiliations
Ergon Energy (Australia) (AU)
Venue
2016 Australasian Universities Power Engineering Conference (AUPEC)
Publisher
IEEE
Published
2016-09
Pages
1-6
OpenAlex
W2554447803
Cited by
7
References
0
Citations by year
2026: 1 · 2024: 2 · 2020: 2 · 2019: 1 · 2017: 1
FWCI
0.94
Type
conference paper
Language
en
Open access
closed
Locations
Australasian Universities Power Engineering Conference (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
Keywords
STATCOM, voltage rise, inverter-based resources, distributed generation, photovoltaic systems, low-voltage distribution networks, voltage regulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›