The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Gait Authentication and Identification Using Wearable Accelerometer Sensor
Abstract
This paper describes gait recognition using a body worn sensor. An accelerometer sensor (placed in the trousers pocket) is used for collecting gait features. From the acceleration signal of the person, cycles have been detected and analysed for recognition. We have applied four different methods (absolute distance, correlation, histogram, and higher order moments) to evaluate performance of the system both in authentication and identification modes. Our data set consists of 300 gait sequences collected from 50 subjects. Absolute distance metric has shown the best performance in terms of EER, which is equal to 7.3% (recognition rate is 86.3%). Furthermore, we have also analysed recognition performance when subjects were carrying a backpack.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The humanID gait challenge problem: data sets, performance, and analysis
Sarkar, S., Phillips, P. J., Liu, Z., Vega, I. R., Grother, P., & Bowyer, K. W. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.39 · Cited by 1,133
Cited by
Feature Selection and Activity Recognition System Using a Single Triaxial Accelerometer
Gupta, P., & Dallas, T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2307069 · Cited by 335
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2020) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2020.2985628 · Cited by 305
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2018) · arXiv · doi:10.48550/arxiv.1811.00338 · Cited by 305
(2019) · ACM Computing Surveys · doi:10.1145/3230633 · Cited by 303
Ngo, T. T., Makihara, Y., Nagahara, H., Mukaigawa, Y., & Yagi, Y. (2014) · Pattern Recognition · doi:10.1016/j.patcog.2013.06.028 · Cited by 281
Metadata
- Authors
- Gafurov, D., Snekkenes, E., & Bours, P.
- Venue
- 2007 IEEE Workshop on Automatic Identification Advanced Technologies
- Publisher
- IEEE
- Published
- 2007-06
- Pages
- 220-225
- OpenAlex
- W2102950522
- Cited by
- 181
- References
- 1
- FWCI
- 15.32
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gait Authentication and Identification Using Wearable Accelerometer Sensor. https://app.cochat.ai/papers/10.1109/autoid.2007.380623
- The paper
- Gafurov, D., Snekkenes, E., & Bours, P. (2007). Gait Authentication and Identification Using Wearable Accelerometer Sensor. 2007 IEEE Workshop on Automatic Identification Advanced Technologies. https://doi.org/10.1109/autoid.2007.380623
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.