Adaptive oscillators with human-in-the-loop: Proof of concept for assistance and rehabilitation
Open accessAbstract
Most recent findings in robot-assisted therapy suggest that the therapy is more successful if the patient actively participates to the movement (“assistance-as-needed”). In the present contribution, we propose a novel approach for designing highly flexible protocols based on this concept. This approach uses adaptive oscillators: a mathematical primitive having the capacity to learn the high-level features of a quasi-sinusoidal signal (amplitude, frequency, offset). Using a simple inverse model, we demonstrate that this method permits to synchronize with the torque produced by the user, such that the effort associated with the movement production is shared between the user and the assistance device, without specifying any arbitrary reference trajectory. Simulation results also establish the method relevance for helping patients with movement disorders. Since our method is specifically designed for rhythmic movements, the final target is the assistance/rehabilitation of locomotory tasks. As an initial proof of concept, this paper focuses on a simpler movement, i.e. rhythmic oscillations of the forearm about the elbow.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The control of most haptic guidance feedback strategies is based on reference trajectories, except for zero impedance control and a few model-based algorithms.
“The control of most haptic guidance feedback strategies is based upon reference trajectories, except for zero impedance control and a few model-based control algorithms (Ronsse, Koopman, et al., 2011;Ronsse et al., 2010;Ronsse, Vitiello, et al., 2011).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Ronsse et al., 2010
A recent control concept uses adaptive oscillators that synchronize with sinusoidal high-level features of the user's movements, supporting arbitrary rhythmic movements without reference trajectories.
“In a recent control concept, the haptic controller does not rely on reference trajectories and supports arbitrary rhythmic movements of the user.To do so, the controller uses adaptive oscillators that synchronize with the sinusoidal high-level features of the user's movements (Ronsse, Koopman et al., 2011;Ronsse et al., 2010;Ronsse, Vitiello, et al., 2011).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Ronsse et al., 2010
Cites
Rhythmic arm movement is not discrete
Schaal, S., Sternad, D., Osu, R., & Kawato, M. (2004) · Nature Neuroscience · doi:10.1038/nn1322 · Cited by 368 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416 · see citing works
- Authors
- Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Chiara Carrozza, M., & Ijspeert, A. J.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Scuola Superiore Sant'Anna (IT)
- Venue
- 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics
- Publisher
- IEEE
- Published
- 2010-09
- Pages
- 668-674
- ISSN
- 2155-1774 (ISSN-L)
- OpenAlex
- W2117974171
- Cited by
- 52
- References
- 1
- Citations by year
- 2024: 2 · 2022: 4 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 10 · 2015: 3 · 2014: 3 · 2013: 4 · 2012: 3
- FWCI
- 11.04
- Type
- conference paper
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Licence
- cc-by-nc-nd
- Locations
- IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Digital Access to Libraries (Université catholique de Louvain (UCL), l'Université de Namur (UNamur) and the Université Saint-Louis (USL-B)) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- European Commission (231451)
- FP7 Information and Communication Technologies
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- adaptive oscillators, human-in-the-loop, robot-assisted therapy, inverse model, movement disorders, rehabilitation, rhythmic movement, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review