Abstract
Smart clothes increase the efficiency of long-term non-invasive monitoring systems by facilitating the placement of sensors and increasing the number of measurement locations. Since the sensors are either garment-integrated or embedded in an unobtrusive way in the garment, the impact on the subject's comfort is minimized. However, the main challenge of smart clothing lies in the enhancement of signal quality and the management of the huge data volume resulting from the variable contact with the skin, movement artifacts, non-accurate location of sensors and the large number of acquired signals. This paper exposes the strategies and solutions adopted in the European 1ST project MyHeart to address these problems, from the definition of the body sensor network to the description of two embedded signal processing techniques performing on-body ECG enhancement and motion activity classification
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
“It adopted the use of smart clothes, where the sensing modules are either garmentintegrated or simply embedded on the piece of clothing [26], [27].”
MethodEnabling Effective Programming and Flexible Management of Efficient Body Sensor Network Applications
Fortino, G., Giannantonio, R., Gravina, R., Kuryloski, P., & Jafari, R. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2215852 · Cited by 412
Remote health monitoring of elderly through wearable sensors
Al-khafajiy, M., Baker, T., Chalmers, C., Asim, M., Kolivand, H., Fahim, M., & Waraich, A. (2019) · Multimedia Tools and Applications · doi:10.1007/s11042-018-7134-7 · Cited by 365
Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
Application of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
“Luprano et al. [98] incorporated textile electrodes and an accelerometer into a shirt to measure ECG and perform activity recognition.”
Background
Metadata
- Authors
- Luprano, J., Sola, J., Dasen, S., Koller, J. M., & Chetelat, O.
- Venue
- International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06)
- Publisher
- IEEE
- Published
- 2006-04-28
- Pages
- 76-79
- OpenAlex
- W1920361317
- Cited by
- 89
- References
- 0
- FWCI
- 11.47
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combination of Body Sensor Networks and On-Body Signal Processing Algorithms: the practical case of MyHeart project. https://app.cochat.ai/papers/10.1109/bsn.2006.15
- The paper
- Luprano, J., Sola, J., Dasen, S., Koller, J. M., & Chetelat, O. (2006). Combination of Body Sensor Networks and On-Body Signal Processing Algorithms: the practical case of MyHeart project. International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06). https://doi.org/10.1109/bsn.2006.15
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.