An Ultra Low Power Pulse Oximeter Sensor Based on Compressed Sensing
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We describe an ultra low power pulse oximeter sensor for long term, non-invasive monitoring of SpO2and heart rate in Body Area Networks (BAN). Commercial pulse oximeter sensors consume about 20-60 mW of power during continuous operation. Other researchers have shown that accurate and noise robust wireless pulse oximeter sensors can be designed to operate with as little as 1.5 mW. The LEDs consume bulk of the power budget in pulse oximeter sensors. In this work, we describe a compressed sensing approach to sample the photodetector output, so that the LEDs can be turned off for longer periods and thus save sensor power. We randomly sample Photoplethysmogram (PPG) signals with about 10-40x fewer samples than with uniform sampling and demonstrate that the accuracy of heart rate estimation and blood pressure estimation are not compromised, using MIMIC database. This provides power savings of the order of 10-40x for a pulse oximeter sensor, by reducing the duration LEDs need to be turned on.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“Here we briefly describe the ECG peak extraction algorithm employed in [6], [12].”
MethodStable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235 · cited 1×
“The red and infrared LEDs account for most of this power [3].”
Background
Cited by
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 376
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
Lee, H., Kim, E., Lee, Y., Kim, H., Lee, J., Kim, M., Yoo, H.-J., & Yoo, S. (2018) · Science Advances · doi:10.1126/sciadv.aas9530 · Cited by 274
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
“Other approaches to reduce power consumption include: 1) delaying the next measurement after one of low quality [86]; 2) using compressive sampling to reduce the sampling frequency while still being able to accurately obtain information from PPG pulse waves [270], [271]; and 3) using windowed sampling to only sample p…”
Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time
Shao, D., Yang, Y., Liu, C., Tsow, F., Yu, H., & Tao, N. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2327024 · Cited by 183
“While useful, this approach requires steady physical contact of one’s finger with the PPG devices [7], [8] or the cameras, which makes it impractical for continuous monitoring of the physiological signals under free-living conditions.”
BackgroundAbnormal ECG signal detection based on compressed sampling in Wearable ECG sensor
Ding, H., Sun, H., & Hou, K.-M. (2011) · 2011 International Conference on Wireless Communications and Signal Processing (WCSP) · doi:10.1109/wcsp.2011.6096677 · Cited by 16
Metadata
- Authors
- Baheti, P. K., & Garudadri, H.
- Venue
- 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 144-148
- OpenAlex
- W2128092100
- Cited by
- 96
- References
- 3
- FWCI
- 13.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.