The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Design and Analysis of a Hardware-Efficient Compressed Sensing Architecture for Data Compression in Wireless Sensors
Abstract
This work introduces the use of compressed sensing (CS) algorithms for data compression in wireless sensors to address the energy and telemetry bandwidth constraints common to wireless sensor nodes. Circuit models of both analog and digital implementations of the CS system are presented that enable analysis of the power/performance costs associated with the design space for any potential CS application, including analog-to-information converters (AIC). Results of the analysis show that a digital implementation is significantly more energy-efficient for the wireless sensor space where signals require high gain and medium to high resolutions. The resulting circuit architecture is implemented in a 90 nm CMOS process. Measured power results correlate well with the circuit models, and the test system demonstrates continuous, on-the-fly data processing, resulting in more than an order of magnitude compression for electroencephalography (EEG) signals while consuming only 1.9$\mu$W at 0.6 V for sub-20 kS/s sampling rates. The design and measurement of the proposed architecture is presented in the context of medical sensors, however the tools and insights are generally applicable to any sparse data acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Cited by
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
Energy-Efficient Multi-Mode Compressed Sensing System for Implantable Neural Recordings
Suo, Y., Zhang, J., Xiong, T., Chin, P. S., Etienne-Cummings, R., & Tran, T. D. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2359180 · Cited by 47
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Sparsity-Aware Learning and Compressed Sensing: An Overview
Theodoridis, S., Kopsinis, Y., & Slavakis, K. (2014) · Academic Press Library in Signal Processing · doi:10.1016/b978-0-12-396502-8.00023-1 · Cited by 14
Metadata
- Authors
- Chen, F., Chandrakasan, A. P., & Stojanovic, V. M.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2012-03
- Volume
- 47
- Issue
- 3
- Pages
- 744-756
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2064030771
- Cited by
- 376
- References
- 3
- FWCI
- 38.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Analysis of a Hardware-Efficient Compressed Sensing Architecture for Data Compression in Wireless Sensors. https://app.cochat.ai/papers/10.1109/jssc.2011.2179451
- The paper
- Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012). Design and Analysis of a Hardware-Efficient Compressed Sensing Architecture for Data Compression in Wireless Sensors. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2011.2179451
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.