Using Wearable Sensors to Monitor Physical Activities of Patients with COPD: A Comparison of Classifier Performance
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Chronic obstructive pulmonary disease (COPD) is a major public health problem. Early detection and treatment of an exacerbation in the outpatient setting are important to prevent worsening of clinical status and need for emergency room care or hospital admission. In this study we use accelerometers to capture motion data; and heart rate and respiration rate to capture physiological responses from patients with COPD as they perform a range of Activities of Daily Living (ADL) and physical exercises. We present a comparative analysis of classification performance of a set of different classification techniques and factors that affect classification performance for activity recognition based on accelerometer data. This is the first step towards building a wearable sensor monitoring system for tracking changes in physiological responses of patients with COPD with respect to their physical activity level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Tapia, E. M., Intille, S. S., Haskell, W., Larson, K., Wright, J., King, A., & Friedman, R. (2007) · 2007 11th IEEE International Symposium on Wearable Computers · doi:10.1109/iswc.2007.4373774 · Cited by 458 · cited 1×
“Prior work [5,6,14] demonstrates that activity recognition with a high degree of accuracy can be achieved using body worn accelerometers.”
Background
Cited by
Human Behavior Analysis by Means of Multimodal Context Mining
Banos, O., Villalonga, C., Bang, J., Hur, T., Kang, D., Park, S., Huynh-The, T., Le-Ba, V., Amin, M., Razzaq, M., et al. (2016) · Sensors · doi:10.3390/s16081264 · Cited by 450
A Survey on Activity Detection and Classification Using Wearable Sensors
Cornacchia, M., Ozcan, K., Zheng, Y., & Velipasalar, S. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2628346 · Cited by 424
Banos, O., Villalonga, C., Garcia, R., Saez, A., Damas, M., Holgado-Terriza, J. A., Lee, S., Pomares, H., & Rojas, I. (2015) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-14-s2-s6 · Cited by 321
Creating and benchmarking a new dataset for physical activity monitoring
Reiss, A., & Stricker, D. (2012) · Proceedings of the 5th International Conference on PErvasive Technologies Related to Assistive Environments · doi:10.1145/2413097.2413148 · Cited by 295
“[13]) showed, that in the trade-off between classification performance and number of sensors, using 3 sensor locations is the most effective.”
BackgroundApplication of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
Metadata
- Authors
- Patel, S., Mancinelli, C., Healey, J., Moy, M., & Bonato, P.
- Venue
- 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 234-239
- OpenAlex
- W2133075061
- Cited by
- 51
- References
- 3
- FWCI
- 3.00
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.