Cited by 458Context-Aware Activity Recognition SystemsPhysical Activity and HealthGait Recognition and Analysis

Real-Time Recognition of Physical Activities and Their Intensities Using Wireless Accelerometers and a Heart Rate Monitor

Tapia, Emmanuel Munguia, Intille, Stephen S., Haskell, William, Larson, Kent, Wright, Julie, King, Abby, Friedman, Robert·2007·2007 11th IEEE International Symposium on Wearable Computers

Abstract

In this paper, we present a real-time algorithm for automatic recognition of not only physical activities, but also, in some cases, their intensities, using five triaxial wireless accelerometers and a wireless heart rate monitor. The algorithm has been evaluated using datasets consisting of 30 physical gymnasium activities collected from a total of 21 people at two different labs. On these activities, we have obtained a recognition accuracy performance of 94.6% using subject-dependent training and 56.3% using subject-independent training. The addition of heart rate data improves subject-dependent recognition accuracy only by 1.2% and subject-independent recognition only by 2.1%. When recognizing activity type without differentiating intensity levels, we obtain a subject-independent performance of 80.6%. We discuss why heart rate data has such little discriminatory power.

Integrity signals

Registry

Crossref · 10.1109/iswc.2007.4373774

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Tapia, E. M., Intille, S. S., Haskell, W., Larson, K., Wright, J., King, A., & Friedman, R.
Affiliations
  • Massachusetts Institute of Technology (US)
  • Stanford University (US)
  • Boston Medical Center (US)
Venue
2007 11th IEEE International Symposium on Wearable Computers
Publisher
IEEE
Published
2007-10
Pages
1-4
ISSN
1550-4816 (ISSN-L)
OpenAlex
W2170724010
Cited by
458
References
10
Citations by year
2026: 1 · 2025: 8 · 2024: 16 · 2023: 16 · 2022: 24 · 2021: 20 · 2020: 32 · 2019: 30 · 2018: 29 · 2017: 38 · 2016: 38 · 2015: 43 · 2014: 28 · 2013: 28 · 2012: 27
FWCI
12.59
Type
conference paper
Language
en
Open access
closed
Locations
Proceedings (publishedVersion)
Funders
  • National Science Foundation
  • National Institutes of Health
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
Keywords
physical activity recognition, activity intensity classification, wireless accelerometers, triaxial accelerometry, heart rate monitoring, real-time recognition, subject-independent recognition, multimodal sensor fusion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review