Cited by 89Wireless Body Area NetworksWireless Sensor Networks for Data AnalysisNon-Invasive Vital Sign Monitoring

A Soldier Health Monitoring System for Military Applications

Lim, Hock Beng, Ma, Di, Wang, Bang, Kalbarczyk, Zbigniew, Iyer, Ravishankar K., Watkin, Kenneth L.·2010·2010 International Conference on Body Sensor Networks

Abstract

With recent advances in technology, various wearable sensors have been developed for the monitoring of human physiological parameters. A Body Sensor Network (BSN) consisting of such physiological and biomedical sensor nodes placed on, near or within a human body can be used for real-time health monitoring. In this paper, we describe an on-going effort to develop a system consisting of interconnected BSNs for real-time health monitoring of soldiers. We discuss the background and an application scenario for this project. We describe the preliminary prototype of the system and present a blast source localization application.

Integrity signals

Registry

Crossref · 10.1109/bsn.2010.58

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wearable technology with AI capabilities may now assess medical data from soldiers and help with difficult diagnoses.

    “Wearable technology with AI capabilities may now assess medical data from soldiers and help with difcult diagnoses.”
  • A body sensor network (BSN) made up of physiological and biomedical sensor nodes located close to or inside a human body can be employed for real-time health monitoring of physiological and biomedical parameters including body temperature, heart rate, EEG, and ECG.

    “For real-time health monitoring of physiological and biomedical parameters, including body temperature, heart rate, EEG, and ECG, a body sensor network (BSN) made up of physiological and biomedical sensor nodes located close to or inside a human body can be employed [102,103].”

Cites

Flagged first, then by citations

1 of the 12 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Lim, H. B., Ma, D., Wang, B., Kalbarczyk, Z., Iyer, R. K., & Watkin, K. L.
Affiliations
  • Nanyang Technological University (SG)
  • University of Illinois Urbana-Champaign (US)
Venue
2010 International Conference on Body Sensor Networks
Publisher
IEEE
Published
2010-06
Pages
246-249
ISSN
2376-8886 (ISSN-L)
OpenAlex
W2113111416
Cited by
89
References
12
Citations by year
2026: 2 · 2025: 4 · 2024: 7 · 2023: 11 · 2022: 14 · 2021: 7 · 2020: 8 · 2019: 8 · 2018: 3 · 2017: 6 · 2016: 6 · 2015: 6 · 2014: 5 · 2013: 1
FWCI
1.47
Type
conference paper
Language
en
Open access
closed
Locations
Wearable and Implantable Body Sensor Networks (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Computer Science › Computer Networks and Communications › Wireless Sensor Networks for Data Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
soldier health monitoring, wireless body area networks, wearable sensors, physiological monitoring, real-time health monitoring, military applications, sensor networks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review