Cited by 15Advanced Radiotherapy TechniquesMedical Image Segmentation TechniquesNon-Invasive Vital Sign Monitoring

Predicting Respiratory Motion for Real-Time Tumour Tracking in Radiotherapy

Open access
Krilavicius, Tomas, Zliobaite, Indre, Simonavicius, Henrikas, Jaruevicius, Laimonas·2016·2016 IEEE 29th International Symposium on Computer-Based Medical Systems (CBMS)

Abstract

Radiation therapy is a local treatment aimed at killing cells in and around a tumor. Accurate predictions of lung tumor motion help to improve the precision of radiation treatment by controlling the position of a patient during radiation treatment. Our goal is to develop an algorithmic solution for predicting the position of a target in 3D in real time. In addition to prediction accuracy and low fluctuation of the prediction signal (jitter) we aim for minimum calibration time each patient at the beginning of the procedure. Our solution is based on a model form from the family of exponential smoothing. Performance is evaluated on clinical datasets capturing different behavior (quiet, talking, laughing), and validated in real-time on a prototype with respiratory motion imitation. Proposed solution (ExSmi) achieves good accuracy of prediction (error 4-9 mm/s) with tolerable jitter values (5 -- 7 mm/s). The solution performs well to be prototyped and deployed in applications of radiotherapy.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/cbms.2016.52

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Registration is of great significance in radiotherapy; it is performed to calculate the offset of the current target from the planned position, and the offset is used to adjust patient position or radiation beam.

    “Moreover, registration is also of great significance in radiotherapy (11, 12); it is performed to calculate the offset of the current target from the planned position, and the offset determined from the registration is used to adjust the patient position or the radiation beam.”

    From A review of deep learning-based deformable medical image registration (2022) · cites this paper as [11]

    The Introduction describes determining a tumour’s current position and compensating for motion by repositioning the beam; the Abstract also mentions controlling the couch or beam. Neither passage describes registration to calculate an offset from the planned position, so the claim’s registration-specific explanation is unsupported. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 17

  1. R. H. Abhilash, S. Chauhan, Empirical modeling of renal motion for im- proved targeting during focused ultrasound surgery, Comput. Biol. Med. 43 (4) (2013) 240-247. doi:10.1016/j.compbiomed.2012.11.006. URL http://dx.doi.org/10.1016/j.compbiomed.2012.11.006 · DOI
  2. R. Abhilash, S. Chauhan, Respiration-induced movement correlation for synchronous noninvasive renal cancer surgery, Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on 59 (7) (2012) 1478-1486.
  3. S. Siva, D. Pham, S. Gill, M. Bressel, K. Dang, T. Devereux, T. Kron, F. Foroudi, An analysis of respiratory induced kidney motion on four- dimensional computed tomography and its implications for stereotactic kidney radiotherapy, Radiation Oncology 8 (1) (2013) 248. doi:10.1186/ 1748-717X-8-248. URL http://www.ro-journal.com/content/8/1/248 · DOI
  4. J. W. Wong, M. B. Sharpe, D. A. Jaffray, V. R. Kini, J. M. Robertson, J. S. Stromberg, A. A. Martinez, The use of active breathing control (ABC) to reduce margin for breathing motion, International Journal of Radiation Oncology Biology Physics 44 (4) (1999) 911-919.
  5. T. Solberg, P. Medin, E. Ramirez, C. Ding, R. Foster, J. Yordy, Commis- sioning and initial stereotactic ablative radiotherapy experience with vero, Journal of Applied Clinical Medical Physics 15 (2). URL http://www.jacmp.org/index.php/jacmp/article/view/4685
  6. Y. Seppenwoolde, R. I. Berbeco, S. Nishioka, H. Shirato, B. Heijmen, Ac- curacy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study, Medical Physics 34 (7) (2007) 2774- 2784. doi:http://dx.doi.org/10.1118/1.2739811. URL http://scitation.aip.org/content/aapm/journal/medphys/34/ 7/10.1118/1.2739811 · DOI
  7. Y. Tsunashima, T. Sakae, Y. Shioyama, K. Kagei, T. Terunuma, A. No- htomi, Y. Akine, Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy, In- ternational Journal of Radiation Oncology Biology Physics 60 (3) (2004) 951-958.
  8. T. Krilavičius, D. Vitkutė-Adžgauskienė, K. Šidlauskas, Simulation of the radiation therapy system for respiratory movement compensation, Journal of Vibroengineering 14 (2012) 99-104.
  9. F. Ernst, A. Schweikard, Predicting respiratory motion signals for image- guided radiotherapy using multi-step linear methods (MULIN), Interna- tional Journal of Computer Assisted Radiology and Surgery 3 (1) (2008) 85-90.
  10. F. Ernst, A. Schlaefer, A. Schweikard, Prediction of respiratory motion with wavelet-based multiscale autoregression, in: Proc. of the 10th int. conf. on Medical image computing and computer-assisted intervention, MICCAI, 2007, pp. 668-675.
  11. C. Herrmann, L. Ma, K. Schilling, Model predictive control for tumor mo- tion compensation in robot assisted radiotherapy, in: Preprints of the 18th IFAC World Congress, Vol. 18, 2011, pp. 5968-5973.
  12. H. Chung, H. Jin, T. Suh, J. Palta, S. Kim, Characterization of a com- mercial add-on couch, HexaPOD T M 6D robotic treatment couchTOP, in: World Congress on Medical Physics and Biomedical Engineering, Vol. 14 of IFMBE Proceedings, Springer, 2007, pp. 1945-1947.
  13. J. Meyer, M. Guckenberger, J. Wilbert, K. Baier, On the use of a Hexa- pod table to improve tumour targeting in radiation therapy, in: M. Habib (Ed.), Bioinspiration and Robotics Walking and Climbing Robots, I-Tech Education and Publishing, 2007, pp. 529-544.
  14. K. L. Man, T. Krilavičius, K. Wan, D. Hughes, K. Lee, Modeling and analy- sis of radiation therapy system with respiratory compensation using uppaal, Proc. of the 9th IEEE Int. Symp. on Parallel and Distributed Processing with Applications Workshops (2011) 50-54.
  15. T. Krilavičius, K. L. Man, Timed model of the radiation therapy system with respiratory motion compensation, in: Proc. of the 6th Int. Conf. on Electrical and Control Technologies, ECT, 2011, pp. 1-4.
  16. A. D. Wiles, D. G. Thompson, D. D. Frantz, Accuracy assessment and interpretation for optical tracking systems, in: Proceedings of the SPIE -The International Society for Optical Engineering, 2004, pp. 421-432.
  17. P. Goodwin, The Holt-Winters approach to exponential smoothing: 50 years old and going strong, Foresight: The International Journal of Applied Forecasting 19 (2010) 30-33.

Cited by

Sorted by citations

Authors
Krilavicius, T., Zliobaite, I., Simonavicius, H., & Jaruevicius, L.
Venue
2016 IEEE 29th International Symposium on Computer-Based Medical Systems (CBMS)
Publisher
IEEE
Published
2016-06
Pages
7-12
ISSN
1063-7125 (ISSN-L)
OpenAlex
W1962651629
Cited by
15
References
0
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 1
FWCI
3.48
Type
conference paper
Language
en
Open access
Locations
  • Proceedings - IEEE Symposium on Computer-Based Medical Systems (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Vytautas Magnus University (submittedVersion)
  • arXiv (Cornell University)
Funders
EyeSight Foundation of Alabama
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
respiratory motion prediction, lung tumor tracking, real-time tracking, radiotherapy, exponential smoothing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review