Measures of unobservability
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
An observed nonlinear dynamics is observable if the mapping from initial condition to output trajectory is one to one. The standard tool for checking observability is the observability rank condition but this only gives a yes or no answer. It does not measure how observable or unobservable the system is. Moreover it requires the ability to differentiate the dynamics and the observations. We introduce new tools, the local unobservability index and the local estimation condition number, to measure the degree of observability or unobservability of a system. To compute these one only needs the ability to simulate the system. We apply these tools to find the best location to put a sensor to observe the flow induced by two point vortices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principal component analysis in linear systems: Controllability, observability, and model reduction
Moore, B. (1981) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1981.1102568 · Cited by 5,282 · cited 1×
“• Moore [ 11 ] empirically calculated the observability gramian for a linear system around the zero state in a similar fashion.”
BackgroundNonlinear controllability and observability
Hermann, R., & Krener, A. (1977) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1977.1101601 · Cited by 2,374 · cited 2×
“The usual tool for checking short time locally observability is the observability rank condition [2], [6], [7].”
BackgroundMethodSelf-citationAcheson, D. J. (1990) · doi:10.1093/oso/9780198596608.001.0001 · Cited by 813
Acheson, D. J. (1991) · The Journal of the Acoustical Society of America · doi:10.1121/1.400751 · Cited by 810 · cited 2×
“So frequently a modified model, the Rankine vortex, is used instead [1], [4].”
MethodA subspace approach to balanced truncation for model reduction of nonlinear control systems
Lall, S., Marsden, J. E., & Glavaški, S. (2002) · International Journal of Robust and Nonlinear Control · doi:10.1002/rnc.657 · Cited by 532 · cited 1×
“• Lall, Marsden and Glavski [9] empirically calculated the observability gramian for a nonlinear system around an equilibrium state in a similar fashion.”
BackgroundObservers and Feedback Control for a Rotating Vortex Pair
Tadmor, G. (2004) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2003.821950 · Cited by 22 · cited 1×
“Other work on the controllability and observability of point vortex systems can be found in [3], [4], [5], [12] and [13] [14].”
BackgroundEulerian and Lagrangian observability of point vortex flows
Krener, A. J. (2008) · Tellus A Dynamic Meteorology and Oceanography · doi:10.1111/j.1600-0870.2008.00347.x · Cited by 11 · cited 3×
“The observability rank condition was used to determine the observability of such flows in [6] and [7].”
BackgroundMethodSelf-citationKrener, A. J. (2008) · Proceedings of the IEEE Conference on Decision & Control, including the Symposium on Adaptive Processes · doi:10.1109/cdc.2008.4738604 · Cited by 7 · cited 3×
“The observability rank condition was used to determine the observability of such flows in [6] and [7].”
BackgroundMethodSelf-citation
Cited by
Inertial space-based orbit estimation: A new measurement model for multiple observers
Hippelheuser, J., & Elgohary, T. A. (2021) · Acta Astronautica · doi:10.1016/j.actaastro.2020.05.033 · Cited by 12
Metadata
- Authors
- Krener, A. J., & Ide, K.
- Venue
- Proceedings of the 48h IEEE Conference on Decision and Control (CDC) held jointly with 2009 28th Chinese Control Conference
- Publisher
- IEEE
- Published
- 2009-12
- Pages
- 6401-6406
- OpenAlex
- W2107612715
- Cited by
- 223
- References
- 8
- FWCI
- 8.39
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measures of unobservability. https://app.cochat.ai/papers/10.1109/cdc.2009.5400067
- The paper
- Krener, A. J., & Ide, K. (2009). Measures of unobservability. Proceedings of the 48h IEEE Conference on Decision and Control (CDC) held jointly with 2009 28th Chinese Control Conference. https://doi.org/10.1109/cdc.2009.5400067
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.