CoChat

Voltage stability indices studies on optimal location of wind farm in distribution network

The DOI matches its Crossref record; 8 of the 9 references it cites were found in a registry or an index.

Abstract

The increasing demand for electrical power contributes major challenges especially in power utilities as one of the main issues is voltage instability. The voltage instability occur in both transmission and distribution network may weaken the whole operation of power system that will significantly limit the growth of load. As a result, voltage collapse blackout occurs in the power system whereas at this point the voltage become uncontrollable. The penetration of Wind Power Plant (WPP) in distribution system may be a good alternative to accommodate this challenge. However, the location of WPP play the important role to fully utilize the power generated by WPP that will not only improve the voltage stability margin but also reduce the power losses and enhance voltage profile. This paper presents the analysis for the selection of the optimal location of WPP integration from voltage stability, voltage profile and total system losses overview. The study was conducted using IEEE 30 Bus test system as the benchmark system and DigSILENT PowerFactory 16 as simulation tools.

Overview

Integrity signals

Registry

Crossref · 10.1109/cencon.2017.8262468

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 4

  1. wane, 2013, Power loss calculation of tranmision line with consideration of voltage stability, International Journal of Enhanced Research in Science Technology & Engineering, 2, 38
  2. zamora, 2015, ASEAN Plan of Action For Energy Cooperation (APAEC) 2016–2025, ASEAN Centre for Energy, 1
  3. mohamed, 1989, A static voltage collapse indicator using line stability factors, Journal of Industrial Technology, 7, 73
  4. 2017, Wind in Power 2016 European Statistics

Cited by

See all 12

Metadata

Authors
Ismail, B., Naain, M. M., Wahab, N. I. A., Shaberon, N. S. M., Awalin, L. J., & Alhamrouni, I.
Affiliations
  • Universiti Putra Malaysia (MY)
  • Brunel University of London (GB)
  • University of Kuala Lumpur (MY)
Venue
2017 IEEE Conference on Energy Conversion (CENCON)
Publisher
IEEE
Published
2017-10
Pages
111-116
OpenAlex
W2782193285
Cited by
12
References
9
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2022: 5 · 2020: 3 · 2019: 1
FWCI
1.55
Type
conference paper
Language
en
Open access
closed
Locations
  • IEEE Conference on Energy Conversion (publishedVersion)
  • Universiti Putra Malaysia Institutional Repository (Universiti Putra Malaysia) (acceptedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power System Optimization
Keywords
voltage stability index, wind farm siting, distribution networks, voltage collapse, voltage profile, power losses, wind power integration, IEEE 30-bus system

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.