The DOI matches its Crossref record.
A database to support development and evaluation of intelligent intensive care monitoring
Abstract
Development and evaluation of automated decision support systems requires large amounts of well-characterized, reproducible test data. The MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database is intended to meet these needs. The database, currently nearing completion, will include 100 patient records, each typically containing between 24 and 48 hours of continuous data recorded from patient monitors in the medical, surgical, and cardiac intensive care units of Boston's Beth Israel Hospital. Each record will be accompanied by detailed clinical data derived from the patient's medical record and from the hospital's on-line medical information systems. We select patients to record from those likely to be hemodynamically unstable during the planned recording period. We expect to complete the selection of the recordings to be included in the database by the end of 1996, and to make the database available to other researchers shortly thereafter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Self-citationMIMIC-IV, a freely accessible electronic health record dataset
Johnson, A. E. W., Bulgarelli, L., Shen, L., Gayles, A., Shammout, A., Horng, S., Pollard, T. J., Hao, S., Moody, B., Gow, B., et al. (2023) · Scientific Data · doi:10.1038/s41597-022-01899-x · Cited by 3,401
Self-citationSaeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
Self-citationPhysioNet: a Web-based resource for the study of physiologic signals
Moody, G. B., Mark, R. G., & Goldberger, A. L. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932728 · Cited by 386
Self-citationBreathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Metadata
- Authors
- Moody, G. B., & Mark, R. G.
- Venue
- Computers in Cardiology 1996
- Publisher
- IEEE
- Published
- 2002-12-23
- Pages
- 657-660
- ISSN
- 0276-6574 (ISSN-L)
- OpenAlex
- W2169713586
- Cited by
- 244
- References
- 0
- FWCI
- 34.04
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A database to support development and evaluation of intelligent intensive care monitoring. https://app.cochat.ai/papers/10.1109/cic.1996.542622
- The paper
- Moody, G. B., & Mark, R. G. (2002). A database to support development and evaluation of intelligent intensive care monitoring. Computers in Cardiology 1996. https://doi.org/10.1109/cic.1996.542622
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.