The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multiscale entropy to distinguish physiologic and synthetic RR time series
Abstract
We address the challenge of distinguishing physiologic interbeat interval time series from those generated by synthetic algorithms via a newly developed multiscale entropy method. Traditional measures of time series complexity only quantify the degree of regularity on a single time scale. However, many physiologic variables, such as heart rate, fluctuate in a very complex manner and present correlations over multiple time scales. We have proposed a new method to calculate multiscale entropy from complex signals. In order to distinguish between physiologic and synthetic time series, we first applied the method to a learning set of RR time series derived from healthy subjects. We empirically established selected criteria characterizing the entropy dependence on scale factor for these datasets. We then applied this algorithm to the CinC 2002 test datasets. Using only the multiscale entropy method, we correctly classified 48 of 50 (96%) time series. In combination with Fourier spectral analysis, we correctly classified all time series.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Multiscale Entropy Analysis of Complex Physiologic Time Series
Costa, M., Goldberger, A. L., & Peng, C.-K. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.068102 · Cited by 3,207
Self-citation
Cited by
Multiscale entropy analysis of biological signals
Costa, M., Goldberger, A. L., & Peng, C.-K. (2005) · Physical Review E · doi:10.1103/physreve.71.021906 · Cited by 2,482
Self-citationIncreased Brain Signal Variability Accompanies Lower Behavioral Variability in Development
McIntosh, A. R., Kovacevic, N., & Itier, R. J. (2008) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000106 · Cited by 431
Li, Y., Mache, M. A., & Todd, T. A. (2019) · Journal of Applied Biomechanics · doi:10.1123/jab.2018-0042 · Cited by 30
Multiscale Cross-Approximate Entropy Analysis as a Measure of Complexity among the Aged and Diabetic
Wu, H.-T., Liu, C.-C., Lo, M.-T., Hsu, P.-C., Liu, A.-B., Chang, K.-Y., & Tang, C.-J. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/324325 · Cited by 29
Metadata
- Authors
- Costa, M., Goldberger, A. L., & Peng, C.-K.
- Venue
- Computers in Cardiology
- Publisher
- IEEE
- Published
- 2003-08-27
- Volume
- 29
- Pages
- 137-140
- ISSN
- 0276-6574 (ISSN-L)
- OpenAlex
- W2108350279
- Cited by
- 160
- References
- 2
- FWCI
- 10.41
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiscale entropy to distinguish physiologic and synthetic RR time series. https://app.cochat.ai/papers/10.1109/cic.2002.1166726
- The paper
- Costa, M., Goldberger, A. L., & Peng, C.-K. (2003). Multiscale entropy to distinguish physiologic and synthetic RR time series. Computers in Cardiology. https://doi.org/10.1109/cic.2002.1166726
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.