A signal-agnostic compressed sensing acquisition system for wireless and implantable sensors
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A signal-agnostic compressed sensing (CS) acquisition system is presented that addresses both the energy and telemetry bandwidth constraints of wireless sensors. The CS system enables continuous data acquisition and compression that are suitable for a variety of biophysical signals. A hardware efficient realization of the CS sampling demonstrates data compression up to 40x on an EEG signal while maintaining low perceptual loss in the reconstructed signal. The proposed system also simultaneously relaxes the noise and resolution constraints of the analog front end (AFE) and ADC by nearly an order of magnitude. The CS sampling hardware is implemented in a 90 nm CMOS process and consumes 1.9 μW at 0.6 V and 20 kS/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
Cited by
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 376
Self-citationCompressed Sensing System Considerations for ECG and EMG Wireless Biosensors
Dixon, A. M. R., Allstot, E. G., Gangopadhyay, D., & Allstot, D. J. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2193668 · Cited by 311
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
Secure and Lightweight Compressive Sensing Using Stream Cipher
Pudi, V., Chattopadhyay, A., & Lam, K.-Y. (2018) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2017.2715659 · Cited by 31
Pham, N., Jia, H., Tran, M., Dinh, T., Bui, N., Kwon, Y., Ma, D., Nguyen, P., Mascolo, C., & Vu, T. (2022) · Proceedings of the 28th Annual International Conference on Mobile Computing And Networking · doi:10.1145/3495243.3560533 · Cited by 12
Metadata
- Authors
- Chen, F., Chandrakasan, A. P., & Stojanovic, V.
- Venue
- IEEE Custom Integrated Circuits Conference 2010
- Publisher
- IEEE
- Published
- 2010-09
- Pages
- 1-4
- OpenAlex
- W2005186928
- Cited by
- 79
- References
- 2
- FWCI
- 17.71
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A signal-agnostic compressed sensing acquisition system for wireless and implantable sensors. https://app.cochat.ai/papers/10.1109/cicc.2010.5617383
- The paper
- Chen, F., Chandrakasan, A. P., & Stojanovic, V. (2010). A signal-agnostic compressed sensing acquisition system for wireless and implantable sensors. IEEE Custom Integrated Circuits Conference 2010. https://doi.org/10.1109/cicc.2010.5617383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.