A Boosting Approach to P300 Detection with Application to Brain-Computer Interfaces
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Gradient boosting is a machine learning method, that builds one strong classifier from many weak classifiers. In this work, an algorithm based on gradient boosting is presented, that detects event-related potentials in single electroencephalogram (EEG) trials. The algorithm is used to detect the P300 in the human EEG and to build a brain-computer interface (BCI), specifically a spelling device. Important features of the method described here are its high classification accuracy and its conceptual simplicity. The algorithm was tested with datasets recorded in our lab and one benchmark dataset from the BCI Competition 2003. The number of correctly inferred symbols with the P300 speller paradigm varied between 90% and 100%. In particular, all of the inferred symbols were correct for the BCI competition dataset
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Friedman, J., Hastie, T., & Tibshirani, R. (2000) · The Annals of Statistics · doi:10.1214/aos/1016218223 · Cited by 6,884
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 13×
“On the P300 dataset from the BCI Competition 2003, gradient boosting has a slight advantage over the results of the competition winners (see Sec.”
MethodInfluential
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Self-citationConvolutional Neural Networks for P300 Detection with Application to Brain-Computer Interfaces
Cecotti, H., & Graser, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.125 · Cited by 778
xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537
“For instance, Rakotomamonjy and Guigue [11] used as a classifier an ensemble of several linear support vector machines (SVMs) [12] with an automatic channels selection, and Hoffmann et al. [13] proposed a boosting approach.”
MethodAn adaptive P300-based control system
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036006 · Cited by 158
“P300 BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al…”
Method
Metadata
- Authors
- Hoffmann, U., Garcia, G., Vesin, J.-M., Diserens, K., & Ebrahimi, T.
- Venue
- Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005.
- Publisher
- IEEE
- Published
- 2005-04-19
- Pages
- 97-100
- OpenAlex
- W1770177499
- Cited by
- 89
- References
- 2
- FWCI
- 10.54
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.