An adaptive P300 brain-computer interface (BCI) using a 12 × 7 matrix explored new paradigms to improve bit rate and accuracy. During online use, the system adaptively selects the number of flashes to average. Five different flash patterns were tested. The 19-flash paradigm represents the typical row/column presentation (i.e. 12 columns and 7 rows). The 9- and 14-flash A and B paradigms present all items of the 12 × 7 matrix three times using either 9 or 14 flashes (instead of 19), decreasing the amount of time to present stimuli. Compared to 9-flash A, 9-flash B decreased the likelihood that neighboring items would flash when the target was not flashing, thereby reducing the interference from items adjacent to targets. 14-flash A also reduced the adjacent item interference and 14-flash B additionally eliminated successive (double) flashes of the same item. Results showed that the accuracy and bit rate of the adaptive system were higher than those of the non-adaptive system. In addition, 9- and 14-flash B produced significantly higher performance than their respective A conditions. The results also show the trend that the 14-flash B paradigm was better than the 19-flash pattern for naive users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Indeed, this precedent was established in the first P300 BCI paper (Farwell and Donchin 1988) and has since become commonplace (Lenhardt et al 2008, Krusienski et al 2008, Jin et al 2010a).”
BackgroundTemporary suppression of visual processing in an RSVP task: An attentional blink?
Raymond, J. E., Shapiro, K. L., & Arnell, K. M. (1992) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037//0096-1523.18.3.849 · Cited by 2,260
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990 · cited 1×
“…have been widely used and validated with able-bodied and disabled subjects, who often attain satisfactory results even without extensive training (Pfurtscheller and Neuper 2001, Neuper et al 2003, Pfurtscheller et al 2003, Scherer et al 2004, K ¨ubler et al 2005, Vaughan et al 2006, Blankertz et…”
BackgroundSelf-citationTemporary suppression of visual processing in an RSVP task: an attentional blink?
Raymond, J. E., Shapiro, K. L., & Arnell, K. M. (1992) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037/0096-1523.18.3.849 · Cited by 1,649 · cited 1×
“Reducing the interference from neighboring flashing characters can decrease this ‘attentional blink’ (Raymond et al 1992, Vogel and Luck 2002, Fazel-Rezai 2007, Kranczioch et al 2007).”
BackgroundA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 3×
“P300 BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al…”
MethodBrain–computer interfaces: communication and restoration of movement in paralysis
Birbaumer, N., & Cohen, L. G. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125633 · Cited by 754 · cited 1×
“P300-based BCIs work without training, and may work in subjects who are not successful with other approaches (Sellers and Donchin 2006, Birbaumer and Cohen 2007, Allison and Neuper 2010).”
BackgroundToward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 2×
“The most common approach is to apply improved signal processing and machine learning algorithms (Jung et al 2001, Xu et al 2004, Hill et al 2008, Lenhardt et al 2008, Krusienski et al 2008, Guger et al 2009).”
BackgroundMethodA P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711 · cited 3×
“P300-based BCIs work without training, and may work in subjects who are not successful with other approaches (Sellers and Donchin 2006, Birbaumer and Cohen 2007, Allison and Neuper 2010).”
BackgroundSelf-citationRepetition blindness: Type recognition without token individuation
Kanwisher, N. G. (1987) · Cognition · doi:10.1016/0010-0277(87)90016-3 · Cited by 664 · cited 1×
“Furthermore, the user might not see the second flash because of ‘repetition blindness’ (Kanwisher 1987).”
Background
Cited by
Deep learning based on Batch Normalization for P300 signal detection
Liu, M., Wu, W., Gu, Z., Yu, Z., Qi, F., & Li, Y. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.08.039 · Cited by 230
Xu, M., Xiao, X., Wang, Y., Qi, H., Jung, T.-P., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 227
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
A Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
“To fulfill this goal, several P300-based optimal approaches have been developed, focused mainly on the stimulus presentation paradigm design by decreasing the number of flashes per trial [11]–[15].”
MethodYuan, P., Gao, X., Allison, B., Wang, Y., Bin, G., & Gao, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026014 · Cited by 160
“Developing such standards may require significant discussion and compromise, perhaps mediated through a BCI Society and / or workshops or other events (Allison 2011; Allison et al 2013; see future-bnci.org).”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-04-08
- Volume
- 8
- Issue
- 3
- Pages
- 036006
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2089594124
- Cited by
- 158
- References
- 60
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An adaptive P300-based control system. https://app.cochat.ai/papers/10.1088/1741-2560/8/3/036006
- The paper
- Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011). An adaptive P300-based control system. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/3/036006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.