The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Sub-band Common Spatial Pattern (SBCSP) for Brain-Computer Interface
Open accessAbstract
Brain-computer interface (BCI) is a system to translate humans thoughts into commands. For electroencephalography (EEG) based BCI, motor imagery is considered as one of the most effective ways. Different imagery activities can be classified based on the changes in mu and/or beta rhythms and their spatial distributions. However, the change in these rhythmic patterns varies from one subject to another. This causes an unavoidable time-consuming fine-tuning process in building a BCI for every subject. To address this issue, we propose a new method called sub-band common spatial pattern (SBCSP) to solve the problem. First, we decompose the EEG signals into sub-bands using a filter bank. Subsequently, we apply a discriminative analysis to extract SBCSP features. The SBCSP features are then fed into linear discriminant analyzers (LDA) to obtain scores which reflect the classification capability of each frequency band. Finally, the scores are fused to make decision. We evaluate two fusion methods: recursive band elimination (RBE) and meta-classifier (MC). We assess our approaches on a standard database from BCI Competition III. We also compare our method with two other approaches that address the same issue. The results show that our method outperforms the other two approaches and achieves similar result as compared to the best one in the literature which was obtained by a time-consuming fine-tuning process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Gene selection for cancer classification using support vector machines
Guyon, I., Weston, J., Barnhill, S., & Vapnik, V. (2002) · Machine Learning · doi:10.1023/a:1012487302797 · Cited by 9,954
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Barker, L. (2002) · Technometrics · doi:10.1198/tech.2002.s659 · Cited by 2,477
Designing optimal spatial filters for single-trial EEG classification in a movement task
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00038-8 · Cited by 846
Use of the zero norm with linear models and kernel methods
Weston, J., Elisseeff, A., Schölkopf, B., & Tipping, M. (2003) · MPG.PuRe (Max Planck Society) · doi:10.5555/944919.944982 · Cited by 688
Spatio-spectral filters for improving the classification of single trial EEG
Lemm, S., Blankertz, B., Curio, G., & Muller, K.-R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851521 · Cited by 643
BCI competition 2003-data set IIa: spatial patterns of self-controlled brain rhythm modulations
Blanchard, G., & Blankertz, B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826691 · Cited by 132
Cited by
Filter Bank Common Spatial Pattern (FBCSP) in Brain-Computer Interface
Ang, K. K., Chin, Z. Y., Zhang, H., & Guan, C. (2008) · 2008 IEEE International Joint Conference on Neural Networks (IEEE World Congress on Computational Intelligence) · doi:10.1109/ijcnn.2008.4634130 · Cited by 1,514
Self-citationEEG-Based Brain-Computer Interfaces Using Motor-Imagery: Techniques and Challenges
Padfield, N., Zabalza, J., Zhao, H., Masero, V., & Ren, J. (2019) · Sensors · doi:10.3390/s19061423 · Cited by 596
Temporally Constrained Sparse Group Spatial Patterns for Motor Imagery BCI
Zhang, Y., Nam, C. S., Zhou, G., Jin, J., Wang, X., & Cichocki, A. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2841847 · Cited by 330
A New Discriminative Common Spatial Pattern Method for Motor Imagery Brain–Computer Interfaces
Thomas, K. P., Guan, C., Lau, C. T., Vinod, A. P., & Ang, K. K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2026181 · Cited by 321
Self-citationRegularized Common Spatial Pattern With Aggregation for EEG Classification in Small-Sample Setting
Lu, H., Eng, H.-L., Guan, C., Plataniotis, K. N., & Venetsanopoulos, A. N. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082540 · Cited by 309
Self-citation
Metadata
- Authors
- Novi, Q., Guan, C., Dat, T. H., & Xue, P.
- Venue
- 2007 3rd International IEEE/EMBS Conference on Neural Engineering
- Publisher
- IEEE
- Published
- 2007-05
- Pages
- 204-207
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2152863712
- Cited by
- 307
- References
- 9
- FWCI
- 13.80
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.