The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A four-step camera calibration procedure with implicit image correction
Abstract
In geometrical camera calibration the objective is to determine a set of camera parameters that describe the mapping between 3-D reference coordinates and 2-D image coordinates. Various methods for camera calibration can be found from the literature. However surprisingly little attention has been paid to the whole calibration procedure, i.e., control point extraction from images, model fitting, image correction, and errors originating in these stages. The main interest has been in model fitting, although the other stages are also important. In this paper we present a four-step calibration procedure that is an extension to the two-step method. There is an additional step to compensate for distortion caused by circular features, and a step for correcting the distorted image coordinates. The image correction is performed with an empirical inverse model that accurately compensates for radial and tangential distortions. Finally, a linear method for solving the parameters of the inverse model is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsai, R. (1987) · IEEE Journal on Robotics and Automation · doi:10.1109/jra.1987.1087109 · Cited by 5,838
Camera calibration with distortion models and accuracy evaluation
Weng, J., Cohen, P., & Herniou, M. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.159901 · Cited by 1,757
Slama, C. C., Theurer, C. B., & Henriksen, S. W. (1980) · American Society of Photogrammetry eBooks · Cited by 1,072
CALIBRATION OF CLOSE-RANGE PHOTOGRAMMETRIC SYSTEMS: MATHEMATICAL FORMULATION.
Faig, W. (1975) · Photogrammetric Engineering & Remote Sensing · Cited by 220
A complete two-plane camera calibration method and experimental comparisons
Wei, G.-Q., & Ma, S. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.1993.378183 · Cited by 84
Cited by
Soil deformation measurement using particle image velocimetry (PIV) and photogrammetry
White, D. J., Take, W. A., & Bolton, M. D. (2003) · Géotechnique · doi:10.1680/geot.2003.53.7.619 · Cited by 1,508
Hedrick, T. L. (2008) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/3/3/034001 · Cited by 1,360
Berni, J., Zarco-Tejada, P. J., Suarez, L., & Fereres, E. (2009) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2008.2010457 · Cited by 1,308
Automatic camera and range sensor calibration using a single shot
Geiger, A., Moosmann, F., Car, O., & Schuster, B. (2012) · 2012 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2012.6224570 · Cited by 647
Computer Vision for Autonomous Vehicles: Problems, Datasets and State of the Art
Janai, J., Güney, F., Behl, A., & Geiger, A. (2020) · Foundations and Trends® in Computer Graphics and Vision · doi:10.1561/0600000079 · Cited by 643
Metadata
- Authors
- Heikkila, J., & Silven, O.
- Venue
- Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition
- Publisher
- IEEE Comput. Soc
- Published
- 2002-11-22
- Pages
- 1106-1112
- ISSN
- 1063-6919 (ISSN-L)
- OpenAlex
- W2112731915
- Cited by
- 2,051
- References
- 5
- FWCI
- 33.98
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.