The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses
Abstract
A new technique for three-dimensional (3D) camera calibration for machine vision metrology using off-the-shelf TV cameras and lenses is described. The two-stage technique is aimed at efficient computation of camera external position and orientation relative to object reference coordinate system as well as the effective focal length, radial lens distortion, and image scanning parameters. The two-stage technique has advantage in terms of accuracy, speed, and versatility over existing state of the art. A critical review of the state of the art is given in the beginning. A theoretical framework is established, supported by comprehensive proof in five appendixes, and may pave the way for future research on 3D robotics vision. Test results using real data are described. Both accuracy and speed are reported. The experimental results are analyzed and compared with theoretical prediction. Recent effort indicates that with slight modification, the two-stage calibration can be done in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
Cited by
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
Hedrick, T. L. (2008) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/3/3/034001 · Cited by 1,360
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Monocular model-based 3D tracking of rigid objects: a survey
Lepetit, V., & Fua, P. (2005) · Foundations and Trends® in Computer Graphics and Vision · doi:10.1561/0600000001 · Cited by 484
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
Metadata
- Authors
- Tsai, R.
- Venue
- IEEE Journal on Robotics and Automation
- Published
- 1987-08
- Volume
- 3
- Issue
- 4
- Pages
- 323-344
- ISSN
- 0882-4967 (ISSN-L)
- OpenAlex
- W2124535811
- Cited by
- 5,838
- References
- 1
- FWCI
- 31.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. https://app.cochat.ai/papers/10.1109/jra.1987.1087109
- The paper
- Tsai, R. (1987). A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE Journal on Robotics and Automation. https://doi.org/10.1109/jra.1987.1087109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.