The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Radiometric self calibration
Abstract
A simple algorithm is described that computes the radiometric response function of an imaging system, from images of an arbitrary scene taken using different exposures. The exposure is varied by changing either the aperture setting or the shutter speed. The algorithm does not require precise estimates of the exposures used. Rough estimates of the ratios of the exposures (e.g. F-number settings on an inexpensive lens) are sufficient for accurate recovery of the response function as well as the actual exposure ratios. The computed response function is used to fuse the multiple images into a single high dynamic range radiance image. Robustness is tested using a variety of scenes and cameras as well as noisy synthetic images generated using 100 randomly selected response curves. Automatic rejection of image areas that have large vignetting effects or temporal scene variations make the algorithm applicable to not just photographic but also video cameras.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1986) · Cited by 3,616
Recovering high dynamic range radiance maps from photographs
Debevec, P. E., & Malik, J. (2008) · ACM SIGGRAPH 2008 classes · doi:10.1145/1401132.1401174 · Cited by 2,399
Recovering high dynamic range radiance maps from photographs
Debevec, P. E., & Malik, J. (1997) · Proceedings of the 24th annual conference on Computer graphics and interactive techniques - SIGGRAPH '97 · doi:10.1145/258734.258884 · Cited by 1,775
The Theory of the Photographic Process
James, T. H., & McCarthy, M. F. (1966) · Physics Today · doi:10.1063/1.3047790 · Cited by 913
Radiometric CCD camera calibration and noise estimation
Healey, G. E., & Kondepudy, R. (1994) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.276126 · Cited by 739
(1975) · International Linear Collider · Cited by 568
A Technical Introduction to Digital Video
Poynton, C. A. (1996) · Cited by 412
Data Analysis for Scientists and Engineers
Robinson, E. L. (2016) · Princeton University Press eBooks · doi:10.1515/9781400883066 · Cited by 32
Cited by
Contrast restoration of weather degraded images
Narasimhan, S. G., & Nayar, S. K. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1201821 · Cited by 1,642
Self-citationImage Alignment and Stitching: A Tutorial
Szeliski, R. (2007) · Foundations and Trends in Computer Graphics and Vision · doi:10.1561/0600000009 · Cited by 1,593
High dynamic range imaging: spatially varying pixel exposures
Nayar, S. K., & Mitsunaga, T. (2002) · Proceedings IEEE Conference on Computer Vision and Pattern Recognition. CVPR 2000 (Cat. No.PR00662) · doi:10.1109/cvpr.2000.855857 · Cited by 542
Self-citationRobust patch-based hdr reconstruction of dynamic scenes
Sen, P., Kalantari, N. K., Yaesoubi, M., Darabi, S., Goldman, D. B., & Shechtman, E. (2012) · ACM Transactions on Graphics · doi:10.1145/2366145.2366222 · Cited by 433
Kang, S. B., Uyttendaele, M., Winder, S., & Szeliski, R. (2003) · ACM SIGGRAPH 2003 Papers · doi:10.1145/1201775.882270 · Cited by 395
Metadata
- Authors
- Mitsunaga, T., & Nayar, S. K.
- Venue
- Proceedings. 1999 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No PR00149)
- Publisher
- IEEE Comput. Soc
- Published
- 2003-01-20
- Pages
- 374-380
- ISSN
- 1063-6919 (ISSN-L)
- OpenAlex
- W2130700878
- Cited by
- 716
- References
- 8
- FWCI
- 27.64
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiometric self calibration. https://app.cochat.ai/papers/10.1109/cvpr.1999.786966
- The paper
- Mitsunaga, T., & Nayar, S. K. (2003). Radiometric self calibration. Proceedings. 1999 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No PR00149). https://doi.org/10.1109/cvpr.1999.786966
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.