Dynamic Environment Exploration Using a Virtual White Cane
The DOI matches its Crossref record.
Abstract
The virtual white cane is a range sensing device based on active triangulation, that can measure distances at a rate of 15 measurements/second. A blind person can use this device for sensing the environment, pointing it as if it was a flashlight. Beside measuring distances, this device can detect surface discontinuities, such as the foot of a wall, a step, or a drop-off. This is obtained by analyzing the range data collected as the user swings the device around, tracking planar patches and finding discontinuities. In this paper we briefly describe the range sensing device, and present an online surface tracking algorithm, based on a Jump-Markov model. We show experimental results proving the robustness of the tracking system in real-world conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Consistency Analysis and Improvement of Vision-aided Inertial Navigation
Hesch, J. A., Kottas, D. G., Bowman, S. L., & Roumeliotis, S. I. (2014) · IEEE Transactions on Robotics · doi:10.1109/tro.2013.2277549 · Cited by 266
RGB-D camera based wearable navigation system for the visually impaired
Lee, Y. H., & Medioni, G. (2016) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2016.03.019 · Cited by 143
“Researchers have proposed utilizing laser of sensors to replace the white cane [22, 23].”
BackgroundMethodA novel obstacle detection method based on deformable grid for the visually impaired
Kang, M.-C., Chae, S.-H., Sun, J.-Y., Yoo, J.-W., & Ko, S.-J. (2015) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2015.7298298 · Cited by 43
“These devices obtain the information about the surrounding environment by using various sensors including the ultrasonic sensor [2], the laser scanner [3], TOF (Time-of-flight) camera [4], the stereo vision camera [5], [6], and the monocular vision camera.”
MethodAn enhanced obstacle avoidance method for the visually impaired using deformable grid
Kang, M.-C., Chae, S.-H., Sun, J.-Y., Lee, S.-H., & Ko, S.-J. (2017) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2017.014832 · Cited by 36
“These devices acquire information regarding the surrounding environment using various sensors, including ultrasonic sensors [3]-[6], laser scanners [7], stereo vision cameras [8], [9], and monocular vision cameras.”
Background
Metadata
- Authors
- Yuan, D., & Manduchi, R.
- Venue
- 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05)
- Publisher
- IEEE
- Published
- 2005-07-27
- Volume
- 1
- Pages
- 243-249
- ISSN
- 1063-6919 (ISSN-L)
- OpenAlex
- W2115247917
- Cited by
- 81
- References
- 0
- FWCI
- 2.06
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.