Real-time 3D segmentation of the left ventricle using deformable subdivision surfaces
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this paper, we extend a computationally efficient framework for real-time 3D tracking and segmentation to support deformable subdivision surfaces. Segmentation is performed in a sequential state-estimation fashion, using an extended Kalman filter to estimate shape and pose parameters for the subdivision surface. As an example, we have integrated Doo-Sabin subdivision surfaces into the framework. Furthermore, we provide a method for evaluating basis functions for Doo-Sabin surfaces at arbitrary parameter values. These basis functions are precomputed during initialization, and later used during segmentation to quickly evaluate surface points used for edge detection. Fully automatic tracking and segmentation of the left ventricle is demonstrated in a dataset of 21 3D echocardiography recordings. Successful segmentation was achieved in all cases, with limits of agreement (mean plusmn1.96SD) for point to surface distance of 2.2 plusmn 0.8 mm compared to manually verified segmentations. Real-time segmentation at a rate of 25 frames per second consumed a CPU load of 8%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation with Applications to Tracking and Navigation: Theory, Algorithms and Software
Bar‐Shalom, Y., Li, X. ‐., & Kirubarajan, T. (2002) · doi:10.1002/0471221279 · Cited by 6,782
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157 · cited 1×
“Successful segmentation was achieved in all cases, with limits of agreement (mean±1.96SD) for point to surface distance of 2.2±0.8 mm compared to manually verified segmentations.”
InfluentialJacob, G., Noble, J. A., Behrenbruch, C., Kelion, A. D., & Banning, A. P. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996341 · Cited by 142 · cited 1×
“Real-time segmentation at a rate of 25 frames per second consumed a CPU load of 8%.”
Cited by
Standardized Evaluation System for Left Ventricular Segmentation Algorithms in 3D Echocardiography
Bernard, O., Bosch, J. G., Heyde, B., Alessandrini, M., Barbosa, D., Camarasu-Pop, S., Cervenansky, F., Valette, S., Mirea, O., Bernier, M., et al. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2503890 · Cited by 110
Realtime Automatic Assessment of Cardiac Function in Echocardiography
Storve, S., Grue, J. F., Samstad, S., Dalen, H., Haugen, B. O., & Torp, H. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2016.2518306 · Cited by 23
Realtime automatic detection of heart failure in echocardiography
Storve, S., Grue, J. F., Samstad, S., Dalen, H., Haugen, B. O., & Torp, H. (2014) · 2014 IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2014.0262 · Cited by 3
“For more details we refer to [5], [7].”
Background
Metadata
- Authors
- Orderud, F., & Rabben, S. I.
- Venue
- 2008 IEEE Conference on Computer Vision and Pattern Recognition
- Publisher
- IEEE
- Published
- 2008-06
- Pages
- 1-8
- ISSN
- 1063-6919 (ISSN-L)
- OpenAlex
- W2129023614
- Cited by
- 68
- References
- 3
- FWCI
- 6.14
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.