A theory of multi-layer flat refractive geometry
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Flat refractive geometry corresponds to a perspective camera looking through single/multiple parallel flat refractive mediums. We show that the underlying geometry of rays corresponds to an axial camera. This realization, while missing from previous works, leads us to develop a general theory of calibrating such systems using 2D-3D correspondences. The pose of 3D points is assumed to be unknown and is also recovered. Calibration can be done even using a single image of a plane. We show that the unknown orientation of the refracting layers corresponds to the underlying axis, and can be obtained independently of the number of layers, their distances from the camera and their refractive indices. Interestingly, the axis estimation can be mapped to the classical essential matrix computation and 5-point algorithm [15] can be used. After computing the axis, the thicknesses of layers can be obtained linearly when refractive indices are known, and we derive analytical solutions when they are unknown. We also derive the analytical forward projection (AFP) equations to compute the projection of a 3D point via multiple flat refractions, which allows non-linear refinement by minimizing the reprojection error. For two refractions, AFP is either 4th or 12th degree equation depending on the refractive indices. We analyze ambiguities due to small field of view, stability under noise, and show how a two layer system can be well approximated as a single layer system. Real experiments using a water tank validate our theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple View Geometry in Computer Vision
Hartley, R., & Zisserman, A. (2004) · doi:10.1017/cbo9780511811685 · Cited by 21,070
An efficient solution to the five-point relative pose problem
Nister, D. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.17 · Cited by 2,009
(1994) · Graphics Gems · doi:10.1016/b978-0-12-336156-1.50041-0 · Cited by 973
Parameter-Free Radial Distortion Correction with Center of Distortion Estimation
Hartley, R., & Kang, S. B. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1147 · Cited by 292
Pless, R. (2003) · 2003 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, 2003. Proceedings. · doi:10.1109/cvpr.2003.1211520 · Cited by 291 · cited 1×
“Non-Central/Axial Cameras: Pless [16] proposed algorithms for relative motion estimation for calibrated noncentral cameras.”
BackgroundA Generic Concept for Camera Calibration
Sturm, P., & Ramalingam, S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24671-8_1 · Cited by 187 · cited 1×
“Generic camera calibration algorithms [22] have been proposed to calibrate non-central cameras.”
MethodSelf-citationA Theory of Refractive and Specular 3D Shape by Light-Path Triangulation
Kutulakos, K. N., & Steger, E. (2007) · International Journal of Computer Vision · doi:10.1007/s11263-007-0049-9 · Cited by 154 · cited 4×
“Steger and Kutulakos [21] showed that light-path triangulation becomes degenerate when the entire light-path lies on a plane, which is the case here.”
BackgroundResultInfluentialA linear approach to motion estimation using generalized camera models
Li, H., Hartley, R. I., & Kim, J.-H. (2008) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2008.4587545 · Cited by 152 · cited 1×
“[11] analyzed the degeneracies in axial cameras for motion estimation.”
BackgroundMorris, N., & Kutulakos, K. N. (2005) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2005.79 · Cited by 88
Treibitz, T., Schechner, Y. Y., & Singh, H. (2008) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2008.4587844 · Cited by 81 · cited 3×
“This also implies that even when the depth of the calibration object (and hence α) is known as in [25], individual”
BackgroundInfluential
Cited by
Underwater robot sensing technology: A survey
Cong, Y., Gu, C., Zhang, T., & Gao, Y. (2021) · Fundamental Research · doi:10.1016/j.fmre.2021.03.002 · Cited by 181
Metadata
- Authors
- Agrawal, A., Ramalingam, S., Taguchi, Y., & Chari, V.
- Venue
- 2012 IEEE Conference on Computer Vision and Pattern Recognition
- Publisher
- IEEE
- Published
- 2012-06
- Pages
- 3346-3353
- ISSN
- 1063-6919 (ISSN-L)
- OpenAlex
- W2000751449
- Cited by
- 211
- References
- 15
- FWCI
- 7.52
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.