Bearing damage diagnosis by means of the linear discriminant analysis of stator current feature
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Bearing damage is the most common failure in electrical machines. It can be detected by vibration analysis. However, this diagnosis method is costly or not always accessible due to the location of the equipment and the choice of the implemented sensors. An alternative method is provided with the electrical monitoring using the stator current of the electrical machine. This work aims at developing a diagnostic system based on the current feature generated by a frequency selection in the stator current spectrum. The features are evaluated by means of the linear discriminant analysis (LDA) and the fault diagnosis is performed with the Bayes classifier. The proposed method is evaluated by two types of damages at different load cases. The results show that the damaged bearings can be distinguished from the healthy bearing depending on the considered load cases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Diagnostic methods used in PMSMs and reported in the literature for stator current signal analysis include: FFT [116], [131], [132], [135]- [137], ZFFT [133], OA [138] and EPVA [122], DWT [134]- [136] and CWT [136].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [132]
Citations
Cites
Fisher discriminant analysis with kernels
Mika, S., Ratsch, G., Weston, J., Scholkopf, B., & Mullers, K. R. (2003) · Neural Networks for Signal Processing IX: Proceedings of the 1999 IEEE Signal Processing Society Workshop (Cat. No.98TH8468) · doi:10.1109/nnsp.1999.788121 · Cited by 2,661
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartfield, R. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475697 · Cited by 761
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartheld, R. G. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345491 · Cited by 638
Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Motor Bearing Fault Diagnosis Using Trace Ratio Linear Discriminant Analysis
Jin, X., Zhao, M., Chow, T. W. S., & Pecht, M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273471 · Cited by 423
Condition Monitoring of Rotating Electrical Machines
Tavner, P., Ran, L., Penman, J., & Sedding, H. (2008) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo056e · Cited by 331
Immovilli, F., Cocconcelli, M., Bellini, A., & Rubini, R. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025288 · Cited by 201
Incipient Bearing Fault Detection via Motor Stator Current Noise Cancellation Using Wiener Filter
Zhou, W., Lu, B., Habetler, T. G., & Harley, R. G. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2023566 · Cited by 165
Condition Monitoring of Rotating Electrical Machines
Tavner, P., Ran, L., & Crabtree, C. (2020) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo145e · Cited by 149
Research works printed but not linked: 1
- lessmeier, 2012, Untersuchung von Bauteilschäden elektrischer Antriebsstränge im Belastungsprüfstand mittels Statorstromanalyse, ANT Journal Technische Fachzeitschriften der Vereinigten Fachverlage GmbH, 1, 8
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[116], [131], [132], [135]-[137] Stator current FFT fb =fs±kfu fu – characteristic failure frequency of the bearing k=1,2,3.”
BackgroundMethodInfluentialVlachou, V. I., Karakatsanis, T. S., Efstathiou, D. E., Vlachou, E. I., Vologiannidis, S. D., Balaska, V. E., & Gasteratos, A. C. (2025) · Machines · doi:10.3390/machines13070549 · Cited by 22
Chommuangpuck, P., Wanglomklang, T., & Srisertpol, J. (2021) · Systems Science & Control Engineering · doi:10.1080/21642583.2021.1895901 · Cited by 20
Navarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
Jiang, Y., Liu, Y., & Wang, S. (2024) · Structural Control and Health Monitoring · doi:10.1155/2024/6650582 · Cited by 11
Metadata
- Authors
- Mbo'o, C. P., & Hameyer, K.
- Affiliations
- RWTH Aachen University (DE)
- Venue
- 2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)
- Publisher
- IEEE
- Published
- 2015-09
- Pages
- 296-302
- OpenAlex
- W1913941272
- Cited by
- 11
- References
- 20
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 1 · 2022: 1 · 2021: 2 · 2019: 2
- FWCI
- 0.00
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) (publishedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical Fault Detection and Protection
- Keywords
- bearing fault diagnosis, stator current, linear discriminant analysis, Bayesian classifier, frequency spectrum features, bearing damage detection, load cases
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bearing damage diagnosis by means of the linear discriminant analysis of stator current feature. https://app.cochat.ai/papers/10.1109/demped.2015.7303705
- The paper
- Mbo'o, C. P., & Hameyer, K. (2015). Bearing damage diagnosis by means of the linear discriminant analysis of stator current feature. 2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED). https://doi.org/10.1109/demped.2015.7303705
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.