The DOI matches its Crossref record.
Incipient Bearing Fault Detection via Motor Stator Current Noise Cancellation Using Wiener Filter
Abstract
Current-based monitoring can offer significant economic savings and implementation advantages over traditional vibration monitoring for bearing fault detection. The key issue in current-based bearing fault detection is to extract bearing fault signatures from the motor stator current. Since the bearing fault signature in the stator current is typically very subtle, particularly when the fault is at an incipient stage, it is difficult to detect the fault signature directly. Therefore, in this paper, the bearing fault signature is detected alternatively by estimating and removing nonbearing fault components via a noise cancellation method. In this method, all the components of the stator current that are not related to bearing faults are regarded as noise and are estimated by a Wiener filter. Then, all these noise components are cancelled out by their estimates in a real-time fashion, and a fault indicator is established based on the remaining components which are mainly caused by bearing faults. Machine parameters, bearing dimensions, nameplate values, and the stator current spectrum distribution are not required in the method. The results of online experiments with a 20-hp induction motor under multiple load levels have confirmed the effectiveness of this method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Vibration analysis for bearing fault detection and classification using an intelligent filter
Zarei, J., Tajeddini, M. A., & Karimi, H. R. (2014) · Mechatronics · doi:10.1016/j.mechatronics.2014.01.003 · Cited by 269
A novel method based on self-sensing motor drive system for misalignment detection
Yao, Y., Li, Y., & Yin, Q. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.06.030 · Cited by 42
An effective method for detection of stator fault in PMSM with 1D-LBP
Mi̇naz, M. R. (2020) · ISA Transactions · doi:10.1016/j.isatra.2020.07.013 · Cited by 23
Bearing damage diagnosis by means of the linear discriminant analysis of stator current feature
Mbo'o, C. P., & Hameyer, K. (2015) · 2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303705 · Cited by 11
Metadata
- Authors
- Zhou, W., Lu, B., Habetler, T. G., & Harley, R. G.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009-07
- Volume
- 45
- Issue
- 4
- Pages
- 1309-1317
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2096764068
- Cited by
- 165
- References
- 0
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incipient Bearing Fault Detection via Motor Stator Current Noise Cancellation Using Wiener Filter. https://app.cochat.ai/papers/10.1109/tia.2009.2023566
- The paper
- Zhou, W., Lu, B., Habetler, T. G., & Harley, R. G. (2009). Incipient Bearing Fault Detection via Motor Stator Current Noise Cancellation Using Wiener Filter. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2009.2023566
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.