CoChat

Fault Detection of PMSM under Non-Stationary Conditions Based on Wavelet Transformation Combined with Distance Approach

Park, Chan Hee, Lee, Junmin, Ahn, Giljun, Youn, Myeongbaek, Youn, Byeng D. · 2019 · 2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

This paper proposes a new method to detect mechanical faults of permanent magnet synchronous motors (PMSMs) under variable speed conditions. Several prior studies have proposed motor current signature analysis (MCSA) based methods for transient conditions; however, these methods have limitations because they require the characteristic frequency of the motor or they only verify the performance of the methods for a restricted time-varying region. Thus, the research outlined in this paper suggests a method for detecting motor faults using stator currents. The proposed method uses two techniques, continuous wavelet transform (CWT) and distance approach. In this method, after the influence of the non-stationary condition is reduced in the wavelet coefficients, the distance of the residual signal from the distribution of normal state is calculated. The performance of the proposed method is confirmed with the simulation result examining unbalance. From the results, the proposed method demonstrates better performance in small-load under non-stationary conditions.

Overview

Integrity signals

Registry

Crossref · 10.1109/demped.2019.8864842

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 16 references

Cited by

See all 22

Metadata

Authors
Park, C. H., Lee, J., Ahn, G., Youn, M., & Youn, B. D.
Affiliations
Seoul National University (KR)
Venue
2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)
Publisher
IEEE
Published
2019-08
Pages
88-93
OpenAlex
W2979739438
Cited by
21
References
16
Citations by year
2025: 3 · 2024: 4 · 2023: 3 · 2022: 6 · 2021: 4 · 2020: 1
FWCI
4.25
Type
conference paper
Language
en
Open access
closed
Locations
  • IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
Keywords
permanent magnet synchronous motor, fault detection, non-stationary conditions, variable speed operation, continuous wavelet transform, stator current, motor current signature analysis, residual signal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fault Detection of PMSM under Non-Stationary Conditions Based on Wavelet Transformation Combined with Distance Approach. https://app.cochat.ai/papers/10.1109/demped.2019.8864842
The paper
Park, C. H., Lee, J., Ahn, G., Youn, M., & Youn, B. D. (2019). Fault Detection of PMSM under Non-Stationary Conditions Based on Wavelet Transformation Combined with Distance Approach. 2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED). https://doi.org/10.1109/demped.2019.8864842

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.