Abstract
This paper proposes a new method to detect mechanical faults of permanent magnet synchronous motors (PMSMs) under variable speed conditions. Several prior studies have proposed motor current signature analysis (MCSA) based methods for transient conditions; however, these methods have limitations because they require the characteristic frequency of the motor or they only verify the performance of the methods for a restricted time-varying region. Thus, the research outlined in this paper suggests a method for detecting motor faults using stator currents. The proposed method uses two techniques, continuous wavelet transform (CWT) and distance approach. In this method, after the influence of the non-stationary condition is reduced in the wavelet coefficients, the distance of the residual signal from the distribution of normal state is calculated. The performance of the proposed method is confirmed with the simulation result examining unbalance. From the results, the proposed method demonstrates better performance in small-load under non-stationary conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The effectiveness of the proposed method is confirmed by simulation studies for small loads under nonstationary conditions.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [167]
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Lee, J., Wu, F., Zhao, W., Ghaffari, M., Liao, L., & Siegel, D. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2013.06.004 · Cited by 1,594
Self-citationAdvances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Riera-Guasp, M., Antonino-Daviu, J. A., Pineda-Sanchez, M., Puche-Panadero, R., & Perez-Cruz, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004378 · Cited by 267
Rosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214
Blodt, M., Bonacci, D., Regnier, J., Chabert, M., & Faucher, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911941 · Cited by 181
Widodo, A., & Yang, B. (2007) · Expert Systems with Applications · doi:10.1016/j.eswa.2007.06.018 · Cited by 150
Rajagopalan, S., Aller, J. M., Restrepo, J. A., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.894699 · Cited by 142
Health Monitoring of Cooling Fans Based on Mahalanobis Distance With mRMR Feature Selection
Jin, X., Ma, E. W. M., Cheng, L. L., & PECHT, M. G. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2187240 · Cited by 100
Sapena-Bañó, Á., Burriel-Valencia, J., Pineda‐Sanchez, M., Puche‐Panadero, R., & Riera‐Guasp, M. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2626008 · Cited by 86
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Motor Fault Diagnostics Based on Current Signatures: A Review
Niu, G., Dong, X., & Chen, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3285999 · Cited by 269
Skowron, M., Orłowska-Kowalska, T., Wolkiewicz, M., & Kowalski, C. T. (2020) · Energies · doi:10.3390/en13061475 · Cited by 125
Park, C. H., Kim, H., Suh, C., Chae, M., Yoon, H., & Youn, B. D. (2022) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2022.108715 · Cited by 70
Self-citationFault Diagnosis of Electric Motors by a Channel-Wise Regulated CNN and Differential of STFT
Mohammad‐Alikhani, A., Jamshidpour, E., Dhale, S., Akrami, M., Pardhan, S., & Nahid‐Mobarakeh, B. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3532556 · Cited by 57
Metadata
- Authors
- Park, C. H., Lee, J., Ahn, G., Youn, M., & Youn, B. D.
- Affiliations
- Seoul National University (KR)
- Venue
- 2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)
- Publisher
- IEEE
- Published
- 2019-08
- Pages
- 88-93
- OpenAlex
- W2979739438
- Cited by
- 21
- References
- 16
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 3 · 2022: 6 · 2021: 4 · 2020: 1
- FWCI
- 4.25
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, fault detection, non-stationary conditions, variable speed operation, continuous wavelet transform, stator current, motor current signature analysis, residual signal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault Detection of PMSM under Non-Stationary Conditions Based on Wavelet Transformation Combined with Distance Approach. https://app.cochat.ai/papers/10.1109/demped.2019.8864842
- The paper
- Park, C. H., Lee, J., Ahn, G., Youn, M., & Youn, B. D. (2019). Fault Detection of PMSM under Non-Stationary Conditions Based on Wavelet Transformation Combined with Distance Approach. 2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED). https://doi.org/10.1109/demped.2019.8864842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.