Abstract
Dual Active Bridge (DAB) topology performs very well for converter output/input ratio close to transformer ratio. However, if a considerable deviation from the transformer ratio is required the conversion efficiency drops significantly. The approach presented in this paper uses variable AC link reactance to improve the DAB performance during operation at light load. The variable reactance is obtained by using a variable frequency in combination with so-called dual leakage transformer. Simple phase-shift control is used, and the switching frequency is varied in order to minimize the peak transformer current. In addition to that, the dual leakage transformer proposed in this paper has a winding configuration yielding a high leakage inductance at low currents and low leakage inductance at high currents. A fully operational prototype was built, demonstrating a power density of 7.1 kW/Liter with forced air cooling, and a peak efficiency at rated 4 kW load equal to 96.6 %. The presented variable reactance approach resulted in more than 10 % efficiency improvement over the conventional DAB design in the most critical point.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 2×
“MOSFETs are used to implement the high current bridge, since the required blocking voltage does not exceed about 100 V. Realization of the bridge structure is quite critical, since the high current to be switched and the low voltage available for the soft-switching capacitors make the ZVS behavior difficult to achieve…”
BackgroundMethodEnergy Management Power Converters in Hybrid Electric and Fuel Cell Vehicles
Lai, J.-S., & Nelson, D. J. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2006.890122 · Cited by 318 · cited 1×
“Among the several topologies that have been proposed in the literature [ 1 ], the Dual Active Bridge (DAB) shown in Fig. 1 is most suitable, due to the reduced number of”
Background
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Closed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635
Optimal ZVS Modulation of Single-Phase Single-Stage Bidirectional DAB AC–DC Converters
Everts, J., Krismer, F., Van den Keybus, J., Driesen, J., & Kolar, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2292026 · Cited by 501
Rodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352
Hossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
Metadata
- Authors
- Guidi, G., Pavlovsky, M., Kawamura, A., Imakubo, T., & Sasaki, Y.
- Venue
- 2010 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2010-09
- Pages
- 830-837
- OpenAlex
- W2007091476
- Cited by
- 80
- References
- 2
- FWCI
- 3.49
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improvement of light load efficiency of Dual Active Bridge DC-DC converter by using dual leakage transformer and variable frequency. https://app.cochat.ai/papers/10.1109/ecce.2010.5617909
- The paper
- Guidi, G., Pavlovsky, M., Kawamura, A., Imakubo, T., & Sasaki, Y. (2010). Improvement of light load efficiency of Dual Active Bridge DC-DC converter by using dual leakage transformer and variable frequency. 2010 IEEE Energy Conversion Congress and Exposition. https://doi.org/10.1109/ecce.2010.5617909
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.