The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
LED lighting flicker and potential health concerns: IEEE standard PAR1789 update
Abstract
The IEEE Standards Working Group, IEEE PAR1789 “Recommending practices for modulating current in High Brightness LEDs for mitigating health risks to viewers” has been formed to advise the lighting industry, ANSI/NEMA, IEC, EnergyStar and other standards groups about the emerging concern of flicker in LED lighting. This paper introduces power electronic designers for LED lighting to health concerns relating to flicker, demonstrates that existing technologies in LED lighting sometimes provide flicker at frequencies that may induce biological human response, and discusses a few methods to consider when trying to mitigate unintentional biological effects of LED lighting. The paper represents on-going work in IEEE PAR1789 that is vital to designing safe LED lamp drivers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photic‐ and Pattern‐induced Seizures: A Review for the Epilepsy Foundation of America Working Group
Fisher, R. S., Harding, G., Erba, G., Barkley, G. L., & Wilkins, A. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.31405.x · Cited by 427
Self-citationWilkins, A. J. (1995) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780198521747.001.0001 · Cited by 235
Self-citationTheory of Flicker and Transient Responses, I Uniform Fields*
Kelly, D. H. (1971) · Journal of the Optical Society of America · doi:10.1364/josa.61.000537 · Cited by 232
Berman, S. M., GREENHOUSE, D. S., Bailey, I. L., Clear, R. D., & Raasch, T. W. (1991) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1991.tb02788.x · Cited by 163
Adaptation from invisible flicker
Shady, S., MacLeod, D. I. A., & Fisher, H. S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0303452101 · Cited by 111 · cited 1×
“A substantial decrement in sensitivity to visible flicker at 30 Hz, used as a testing condition, occurs in normal observers when there is a prior exposure of only 2 minutes duration with flicker frequencies about 20% above the observers critical fusion frequency (CFF) (Shady et al. 2004).”
BackgroundWilkins, A. J. (1986) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872088602800108 · Cited by 111
Self-citationAnalysis of Nonlinearities in the Flicker ERG
Burns, S. A., Elsner, A. E., & Kreitz, M. R. (1992) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1992.tb02882.x · Cited by 98
Fluorescent tube light evokes flicker responses in visual neurons
Eysel, U. T., & Burandt, U. (1984) · Vision Research · doi:10.1016/0042-6989(84)90069-5 · Cited by 55
The effect of flicker from fluorescent lights on mate choice in captive birds
Evans, J. E., Cuthill, I. C., & Bennett, A. T. D. (2006) · Animal Behaviour · doi:10.1016/j.anbehav.2005.10.031 · Cited by 53
The Effects of Flicker on Eye Movement Control
Kennedy, A., & Murray, W. S. (1991) · The Quarterly Journal of Experimental Psychology Section A · doi:10.1080/14640749108401000 · Cited by 49
A Follow‐up Survey on Seizures Induced by Animated Cartoon TV Program “Pocket Monster”
Ishiguro, Y., Takada, H., Watanabe, K., 奥村, 彰., Aso, K., & Ishikawa, T. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.18903.x · Cited by 30
The Effects of Intermittent Illumination on a Visual Inspection Task
Kennedy, A., Brysbaert, M., & Murray, W. S. (1998) · The Quarterly Journal of Experimental Psychology Section A · doi:10.1080/713755746 · Cited by 27
Cited by
Krein, P. T., Balog, R. S., & Mirjafari, M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2186640 · Cited by 520
IoT Goes Nuclear: Creating a ZigBee Chain Reaction
Ronen, E., Shamir, A., Weingarten, A.-O., & OFlynn, C. (2017) · 2017 IEEE Symposium on Security and Privacy (SP) · doi:10.1109/sp.2017.14 · Cited by 445
Brinkel, N. B. G., Gerritsma, M. K., AlSkaif, T. A., Lampropoulos, I., van Voorden, A. M., Fidder, H. A., & van Sark, W. G. J. H. M. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105741 · Cited by 166
“Voltage fluctuations and flicker can cause damage to electrical appliances connected to the grid [5] and light flicker can cause annoyance and health problems to people exposed to it [6,7].”
BackgroundWireless power transfer: systems, circuits, standards, and use cases
Van Mulders, J., Delabie, D., Lecluyse, C., Buyle, C., Callebaut, G., Van der Perre, L., & De Strycker, L. (2022) · Sensors · doi:10.3390/s22155573 · Cited by 141
Investigation of LED Lighting Performance in the Presence of Ripple Injection Load Control Signals
Rahman, O., Elphick, S., Muttaqi, K. M., & David, J. (2018) · 2018 IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2018.8544698 · Cited by 4
Metadata
- Authors
- Wilkins, A., Veitch, J., & Lehman, B.
- Venue
- 2010 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2010-09
- Pages
- 171-178
- OpenAlex
- W2070432943
- Cited by
- 327
- References
- 12
- FWCI
- 13.98
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.