Design considerations of high voltage and high frequency three phase transformer for Solid State Transformer application
The DOI matches its Crossref record.
Abstract
The three-phase Solid State Transformer (SST) is one of the key elements in the Future Renewable Electric Energy Delivery and Management (FREEDM) System. The SST consists of an input rectifier, Dual Active Bridge (DAB) bidirectional dc-dc converter and followed by an inverter for ac voltage output. The DAB converter is a bidirectional dc-dc converter using high frequency transformers to step up or down the voltages at high frequency for a reduction in size while maintaining high efficiency and reliability. The single phase high-frequency high-voltage transformer for two-level DAB has been reported by the authors [2]. In this paper, high frequency three-phase transformer for multi-level (3-level) and multi-phase (three-phase) DAB is designed for three-phase multilevel SST. There are two proposed topologies and for each topology the high voltage and high frequency transformer is designed at 3 kHz and 20 kHz. The proposed transformer designs for electromagnetic, thermal and mechanical analysis are validated with the simulation of Finite Element Analysis software.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
A Bidirectional LLC Resonant Converter With Automatic Forward and Backward Mode Transition
Jiang, T., Zhang, J., Wu, X., Sheng, K., & Wang, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2307329 · Cited by 264
Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295419 · Cited by 48
“8) The proposed strategy is flexible, allows for high switching frequency operation on the PWM rectifiers, while ensuring that the transformer core is operated at constant MF over entire range [22]–[24].”
BackgroundVarajao, D., Miranda, L. M., Araujo, R. E., & Lopes, J. P. (2016) · IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2016.7793779 · Cited by 17
Metadata
- Authors
- Leung, C.-K., Dutta, S., Baek, S., & Bhattacharya, S.
- Venue
- 2010 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2010-09
- Pages
- 1551-1558
- OpenAlex
- W2067416457
- Cited by
- 55
- References
- 0
- FWCI
- 6.11
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.