Wind Turbine Generator–Battery Energy Storage Utility Interface Converter Topology With Medium-Frequency Transformer Link
The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
Abstract
A medium-voltage (MV) wind turbine generator (WTG)-battery energy storage (BESS) grid interface converter topology with medium-frequency (MF) transformer isolation is introduced in this paper. The system forms a three-port network in which several series stacked ac-ac converters transform the low-frequency (50/60 Hz) utility MV into MF (0.4 to 2 kHz) ac voltage by modulating it with MF square wave. This voltage is then fed to the MF transformer primary windings. The secondary and tertiary windings interface with the WTG side and the BESS side, respectively, after power conversion. The power generated by WTG is transferred to the MF transformer secondary windings through a three-phase pulse width modulation (PWM) rectifier and a three-phase PWM inverter, whereas the power transfer between the BESS and the tertiary winding occurs through a three-phase PWM inverter. It is shown that the utility grid sinusoidal currents, the battery current, and the WTG output currents can be controlled to be of good quality using PI and DQ control strategies. Thus, the proposed MF transformer-based three-port topology results in smaller converter weight/volume. Moreover, the control can handle voltage sags/swells and provide low voltage ride-through capability. Simulation waveforms along with experimental results are shown as proof of concept.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Energy storage systems for advanced power applications
Ribeiro, P. F., Johnson, B. K., Crow, M. L., Arsoy, A., & Liu, Y. (2001) · Proceedings of the IEEE · doi:10.1109/5.975900 · Cited by 1,058
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889939 · Cited by 669 · cited 1×
“Several approaches have been reported in the literature to interface battery energy storage systems (BESSs) with the utility [5]–[8].”
BackgroundVoltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
Maharjan, L., Inoue, S., Akagi, H., & Asakura, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014868 · Cited by 590 · cited 1×
“However, their interface to the utility grid is challenging, especially in the medium-voltage (MV) scale [1]–[4].”
BackgroundFalcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501
Krishnaswami, H., & Mohan, N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022756 · Cited by 411 · cited 1×
“Three-port configurations using dual/triple active bridges to interface renewable energy sources are proposed in [17] and [18].”
BackgroundBragard, M., Soltau, N., Thomas, S., & De Doncker, R. W. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2085455 · Cited by 366 · cited 1×
“Many topologies to interface BESS with WTG systems have also been proposed and/or evaluated [15], [16].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 1×
“tures (with or without dc link) have been proposed for different applications, that can also be used in case of WTG or BESS interface [10]–[14].”
MethodSolid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310 · cited 1×
“tures (with or without dc link) have been proposed for different applications, that can also be used in case of WTG or BESS interface [10]–[14].”
MethodLVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization
Kim, K.-H., Jeung, Y.-C., Lee, D.-C., & Kim, H.-G. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2171999 · Cited by 280 · cited 1×
“NERC proposed a more stringent requirement for WTGs to remain online even with grid voltage falling to 0 V for a few cycles [25], [26].”
Background
Cited by
Power Electronic Transformer-Based Railway Traction Systems: Challenges and Opportunities
Feng, J., Chu, W. Q., Zhang, Z., & Zhu, Z. Q. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2685464 · Cited by 229
“found in [13], [24], [27], [30], [33], [46], [47], [101], and [178]–[186].”
BackgroundZhao, B., Song, Q., Li, J., Liu, W., Liu, G., & Zhao, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2483543 · Cited by 175
“[15] also proposed a solution to power two isolated system with medium-frequency transformer link.”
BackgroundComprehensive overview of grid interfaced wind energy generation systems
Mahela, O. P., & Shaik, A. G. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.048 · Cited by 163
Liu, J., Yang, J., Zhang, J., Nan, Z., & Zheng, Q. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2679489 · Cited by 146
“Erenow, there are many similar researches, not only in traction onboard application, but also in the utility gird application, and the concepts such as solid-state transformer [8], universal and flexible power management [9], power electronic transformer [10], smart energy router [11], [12], single-phase solid-state p…”
BackgroundGao, R., She, X., Husain, I., & Huang, A. Q. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2679679 · Cited by 76
“A converter structure with medium-frequency transformer link is adopted for the wind generation system with battery storage devices in [9].”
Method
Metadata
- Authors
- Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J.
- Affiliations
- Texas A&M University (US)
- Wilmington College (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-08
- Volume
- 29
- Issue
- 8
- Pages
- 4146-4155
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2056943204
- Cited by
- 48
- References
- 26
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 4 · 2022: 10 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 4 · 2017: 9 · 2016: 6 · 2015: 2 · 2014: 2
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- wind turbine generator, battery energy storage, medium frequency transformer, PWM rectifier, PWM inverter, medium-voltage distribution networks, low-voltage ride-through, voltage sag and swell
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wind Turbine Generator–Battery Energy Storage Utility Interface Converter Topology With Medium-Frequency Transformer Link. https://app.cochat.ai/papers/10.1109/tpel.2013.2295419
- The paper
- Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J. (2014). Wind Turbine Generator–Battery Energy Storage Utility Interface Converter Topology With Medium-Frequency Transformer Link. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2013.2295419
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.