Optimal design and experimental validation of a Medium-Frequency 400kVA power transformer for railway traction applications
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents the application of a Medium-Frequency (MF) Transformer design methodology applied to a 400kVA transformer intended for railway traction multi-voltage applications. First, a full-scale prototype operating at a moderate frequency (;5kHz), a nanocrystalline transformer and a Series Resonant Converter (SRC), which has evolved towards a LLC Resonant Converter. A major volume and weight reduction (more than 85%) has been achieved between both designed transformers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Venkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145 · cited 2×
“On the other hand, with the voltage waveform, core losses (Step 6) are determined using the Improved Generalized Steinmetz Equation (IGSE) [9].”
Method
Cited by
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Garcia-Bediaga, A., Villar, I., Rujas, A., Mir, L., & Rufer, A. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2574499 · Cited by 126
Self-citationBahmani, M. A., Thiringer, T., & Kharezy, M. (2016) · 2016 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2016.7468297 · Cited by 45
Baek, S., & Bhattacharya, S. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2740855 · Cited by 26
SiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction
Adamowicz, M., & Szewczyk, J. (2020) · Energies · doi:10.3390/en13215573 · Cited by 24
Metadata
- Authors
- Villar, I., Mir, L., Etxeberria-Otadui, I., Colmenero, J., Agirre, X., & Nieva, T.
- Venue
- 2012 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2012-09
- Pages
- 684-690
- OpenAlex
- W2117006674
- Cited by
- 64
- References
- 1
- FWCI
- 3.28
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal design and experimental validation of a Medium-Frequency 400kVA power transformer for railway traction applications. https://app.cochat.ai/papers/10.1109/ecce.2012.6342754
- The paper
- Villar, I., Mir, L., Etxeberria-Otadui, I., Colmenero, J., Agirre, X., & Nieva, T. (2012). Optimal design and experimental validation of a Medium-Frequency 400kVA power transformer for railway traction applications. 2012 IEEE Energy Conversion Congress and Exposition (ECCE). https://doi.org/10.1109/ecce.2012.6342754
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.