Optimum number of cascaded cells for high-power medium-voltage multilevel converters
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
When power electronic systems are connected to the medium-voltage grid, often multilevel topologies consisting of a number of cascaded converter cells are considered. For a given grid voltage level, either few cells featuring semiconductors with high blocking voltage capability or many cells using low-voltage semiconductors can be employed. This paper proposes efficiency/power density (η-ρ) Pareto analysis to comprehensively identify the optimum number of cascaded cells. Recent advances in silicon carbide (SiC) semiconductor technology point towards devices with blocking voltages exceeding 15kV. The switching characteristics that hypothetical SiC devices would have to provide in order to realize a simple single-stage full-bridge converter competitive to a multilevel solution are derived and found to be impracticably fast. Furthermore, it is shown that reliability concerns arising with increasing number of cascaded cells can be mitigated by means of redundancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, J., Huang, A., Sung, W., Liu, Y., & Baliga, B. (2009) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2009.932583 · Cited by 260 · cited 1×
“It has been used in a wide range of high power applications such as railway drive systems [8]–[11] or smartgrid applications [15], [29].”
BackgroundMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249
Ortiz, G., Leibl, M., Kolar, J. W., & Apeldoorn, O. (2013) · 2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527217 · Cited by 126 · cited 1×
“Of course, the inductor design, as any other magnetics design, is an η-ρ-Pareto problem on its own as for example discussed in [45] for transformers; while this is not considered here, it could, e.”
BackgroundSelf-citation
Cited by
The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445
Huber, J. E., & Kolar, J. W. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954023 · Cited by 264
Self-citationBriz, F., Lopez, M., Rodriguez, A., & Arias, M. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2611648 · Cited by 171
“This also provides the opportunity to implement redundancy-based fault-tolerant designs [35], [36].”
Background
Metadata
- Authors
- Huber, J. E., & Kolar, J. W.
- Venue
- 2013 IEEE Energy Conversion Congress and Exposition
- Publisher
- IEEE
- Published
- 2013-09
- Pages
- 359-366
- OpenAlex
- W2036716139
- Cited by
- 55
- References
- 3
- FWCI
- 10.99
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimum number of cascaded cells for high-power medium-voltage multilevel converters. https://app.cochat.ai/papers/10.1109/ecce.2013.6646723
- The paper
- Huber, J. E., & Kolar, J. W. (2013). Optimum number of cascaded cells for high-power medium-voltage multilevel converters. 2013 IEEE Energy Conversion Congress and Exposition. https://doi.org/10.1109/ecce.2013.6646723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.