Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

High Frequency Transformer Core Loss Analysis in Isolated Modular Multilevel DC-DC Converter for MVDC Application

Agarwal, Rachit, Martin, Sandro, Shi, Yanjun, Li, Hui · 2019 · 2019 IEEE Energy Conversion Congress and Exposition (ECCE)

Abstract

An Isolated Modular Multilevel DC-DC Converter (iM2DC) operating with Phase Shifted - Square Wave Modulation (PS-SWM) featuring reduced passive components and low Total Device Rating (TDR) for MVDC applications is presented here, and the effect of the PS-SWM modulation scheme on high frequency (HF) transformer core loss is analyzed. A down-scaled iM2DC prototype is built with a 1:1 transformer and it is proved that the transformer losses are not affected by the staircase shaped voltage of the PS-SWM modulation. The transformer core loss is analytically found equal to the core loss obtained with pure square wave voltage excitation with 50% duty ratio. This simplifies the HF transformer design and optimization process for this application. The core loss is experimentally measured and validated.

Overview

Integrity signals

Registry

Crossref · 10.1109/ecce.2019.8912736

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 6

Metadata

Authors
Agarwal, R., Martin, S., Shi, Y., & Li, H.
Affiliations
Florida State University (US)
Venue
2019 IEEE Energy Conversion Congress and Exposition (ECCE)
Publisher
IEEE
Published
2019-09
Pages
6419-6423
OpenAlex
W2990784740
Cited by
6
References
8
Citations by year
2023: 2 · 2022: 3 · 2020: 1
FWCI
1.59
Type
conference paper
Language
en
Open access
closed
Locations
IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
transformer core losses, high-frequency transformer, transformer design optimization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.