The DOI matches its Crossref record.
Start-up, functionalities and protection issues for CHB-based solid state transformers
Open accessAbstract
Solid State Transformers (SSTs) are envisioned as an alternative to conventional Line Frequency Transformers (LFT) able to meed with the requirements of future power systems. Intensive studies covering SSTs' applications, topologies, functionalities and the performance are in progress. Other relevant aspects to consider are the startup (energization) of the transformer as well as its behavior and potential control strategies in the event of anomalies, e.g. imbalances in the load or even short-circuits. This papers addresses all these issues for CHB-based SSTs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Besides, the cost can be further reduced using SAB; because, SAB reduces the number of power devices with unidirectional power flow [144].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [144]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 9
- 10.1109/TIE.2006.882014 · DOI
- 10.1109/APEC.2016.7468235 · DOI
- 10.1109/IECON.2015.7392648 · DOI
- 10.1109/ECCE.2011.6064158 · DOI
- 2009, IEEE Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current Systems, IEEE Std C62 22–2009 (Revision of IEEEStd C62 22-1997), 1
- 1996, Isolation coordination, IEC 60071–2, 1
- 10.1109/PESMG.2013.6672768 · DOI
- 10.1109/TPEL.2008.2006975 · DOI
- kolar, 2014, Solid-state-transformers: key components of future traction and smart grid systems, Proc of the InternationalPower Electronics Conference - ECCE Asia (IPEC), 18
Cited by
Sorted by citations
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“As for now, potential applications could be focused on smart grids and renewable energy [145].”
Background
Metadata
- Authors
- Cuartas, J. M., de la Cruz, A., Briz, F., & Lopez, M.
- Affiliations
- Inael (Spain) (ES)
- Universidad de Oviedo (ES)
- ORCID
- Briz, Fernando
- Venue
- 2017 IEEE International Conference on Environment and Electrical Engineering and 2017 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)
- Publisher
- IEEE
- Published
- 2017-06
- Pages
- 1-5
- OpenAlex
- W2734577780
- Cited by
- 12
- References
- 0
- Citations by year
- 2025: 2 · 2023: 3 · 2021: 3 · 2020: 3 · 2018: 1
- FWCI
- 1.55
- Type
- conference paper
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- Locations
- IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) (publishedVersion)
- Consultation of the Doctoral Thesis Database (TESEO) (Ministerio de Educación, Cultura y Deporte) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, cascaded H-bridge inverter, energization, fault protection, short circuit, load imbalance, control strategy, power converters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›