Pattern recognition control outperforms conventional myoelectric control in upper limb patients with targeted muscle reinnervation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Pattern recognition myoelectric control shows great promise as an alternative to conventional amplitude based control to control multiple degree of freedom prosthetic limbs. Many studies have reported pattern recognition classification error performances of less than 10% during offline tests; however, it remains unclear how this translates to real-time control performance. In this contribution, we compare the real-time control performances between pattern recognition and direct myoelectric control (a popular form of conventional amplitude control) for participants who had received targeted muscle reinnervation. The real-time performance was evaluated during three tasks; 1) a box and blocks task, 2) a clothespin relocation task, and 3) a block stacking task. Our results found that pattern recognition significantly outperformed direct control for all three performance tasks. Furthermore, it was found that pattern recognition was configured much quicker. The classification error of the pattern recognition systems used by the patients was found to be 16% ±(1.6%) suggesting that systems with this error rate may still provide excellent control. Finally, patients qualitatively preferred using pattern recognition control and reported the resulting control to be smoother and more consistent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citation
Cited by
Targeted Muscle Reinnervation and Advanced Prosthetic Arms
Cheesborough, J., Smith, L., Kuiken, T., & Dumanian, G. (2015) · Seminars in Plastic Surgery · doi:10.1055/s-0035-1544166 · Cited by 206
Hargrove, L. J., Miller, L. A., Turner, K., & Kuiken, T. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-14386-w · Cited by 190
Self-citationSalminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
“In patients with IMES, however, the signal quality from the implanted sensors is superior to that from surface systems and allows for direct simultaneous and proportional control without retraining (23, 24).”
Background
Metadata
- Authors
- Hargrove, L. J., Lock, B. A., & Simon, A. M.
- Venue
- 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2013-07
- Volume
- 2013
- Pages
- 1599-1602
- OpenAlex
- W2041493459
- Cited by
- 63
- References
- 2
- FWCI
- 11.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.