Wireless patch sensor for remote monitoring of heart rate, respiration, activity, and falls
The DOI matches its Crossref record.
Abstract
Unobtrusive continuous monitoring of important vital signs and activity metrics has the potential to provide remote health monitoring, at-home screening, and rapid notification of critical events such as heart attacks, falls, or respiratory distress. This paper contains validation results of a wireless Bluetooth Low Energy (BLE) patch sensor consisting of two electrocardiography (ECG) electrodes, a microcontroller, a tri-axial accelerometer, and a BLE transceiver. The sensor measures heart rate, heart rate variability (HRV), respiratory rate, posture, steps, and falls and was evaluated on a total of 25 adult participants who performed breathing exercises, activities of daily living (ADLs), various stretches, stationary cycling, walking/running, and simulated falls. Compared to reference devices, the heart rate measurement had a mean absolute error (MAE) of less than 2 bpm, time-domain HRV measurements had an RMS error of less than 15 ms, respiratory rate had an MAE of 1.1 breaths per minute during metronome breathing, posture detection had an accuracy of over 95% in two of the three patch locations, steps were counted with an absolute error of less than 5%, and falls were detected with a sensitivity of 95.2% and specificity of 100%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearables and the Medical Revolution
Dunn, J., Runge, R., & Snyder, M. (2018) · Personalized Medicine · doi:10.2217/pme-2018-0044 · Cited by 654
“VitalConnect (CA, USA) has also built successful sleep apnea and fall detection algorithms using respiratory rate and accelerometry [48-51].”
Performance Evaluation of Bluetooth Low Energy: A Systematic Review
Tosi, J., Taffoni, F., Santacatterina, M., Sannino, R., & Formica, D. (2017) · Sensors · doi:10.3390/s17122898 · Cited by 243
Leenen, J. P. L., Leerentveld, C., van Dijk, J. D., van Westreenen, H. L., Schoonhoven, L., & Patijn, G. A. (2020) · Journal of Medical Internet Research · doi:10.2196/18636 · Cited by 224
“Eventually, 27 studies that met the eligibility criteria were included [39-65].”
BackgroundMethodInfluentialGarbern, S. C., Mbanjumucyo, G., Umuhoza, C., Sharma, V. K., Mackey, J., Tang, O., Martin, K. D., Twagirumukiza, F. R., Rosman, S. L., McCall, N., et al. (2019) · DIGITAL HEALTH · doi:10.1177/2055207619879349 · Cited by 39
“The vast majority of prior studies evaluating wearable devices have taken place in highly controlled laboratory conditions in stable, healthy volunteers.(12,14) This study’s participants had highly varying ages and clinical acuity—including quite stable patients (often boarding while waiting for an inpatient bed) as w…”
BackgroundMedical Devices for Measuring Respiratory Rate in Children: a Review
Daw, W. (2016) · Journal of Advances in Biomedical Engineering and Technology · doi:10.15379/2409-3394.2016.03.01.04 · Cited by 35
“A further development on this method is a small wireless patch sensor from Vital Connect [18].”
Metadata
- Authors
- Chan, A. M., Selvaraj, N., Ferdosi, N., & Narasimhan, R.
- Venue
- 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2013-07
- Volume
- 2013
- Pages
- 6115-6118
- OpenAlex
- W2159151804
- Cited by
- 105
- References
- 0
- FWCI
- 11.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless patch sensor for remote monitoring of heart rate, respiration, activity, and falls. https://app.cochat.ai/papers/10.1109/embc.2013.6610948
- The paper
- Chan, A. M., Selvaraj, N., Ferdosi, N., & Narasimhan, R. (2013). Wireless patch sensor for remote monitoring of heart rate, respiration, activity, and falls. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). https://doi.org/10.1109/embc.2013.6610948
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.