CoChat

Validation of a wearable biosensor device for vital sign monitoring in septic emergency department patients in Rwanda

Open access

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

Objective: Critical care capabilities needed for the management of septic patients, such as continuous vital sign monitoring, are largely unavailable in most emergency departments (EDs) in low- and middle-income country (LMIC) settings. This study aimed to assess the feasibility and accuracy of using a wireless wearable biosensor device for continuous vital sign monitoring in ED patients with suspected sepsis in an LMIC setting. Methods: This was a prospective observational study of pediatric (≥2 mon) and adult patients with suspected sepsis at the Kigali University Teaching Hospital ED. Heart rate, respiratory rate and temperature measurements were continuously recorded using a wearable biosensor device for the duration of the patients’ ED course and compared to intermittent manually collected vital signs. Results: A total of 42 patients had sufficient data for analysis. Mean duration of monitoring was 32.8 h per patient. Biosensor measurements were strongly correlated with manual measurements for heart rate (r = 0.87, p < 0.001) and respiratory rate (r = 0.75, p < 0.001), although were less strong for temperature (r = 0.61, p < 0.001). Mean (SD) differences between biosensor and manual measurements were 1.2 (11.4) beats/min, 2.5 (5.5) breaths/min and 1.4 (1.0)°C. Technical or practical feasibility issues occurred in 12 patients (28.6%) although were minor and included biosensor detachment, connectivity problems, removal for a radiologic study or exam, and patient/parent desire to remove the device. Conclusions: Wearable biosensor devices can be feasibly implemented and provide accurate continuous heart rate and respiratory rate monitoring in acutely ill pediatric and adult ED patients with sepsis in an LMIC setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2055207619879349

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. The VitalPatch (a) and display screen showing a participant's electrocardiogram signal on a Samsung Galaxy J3 smartphone running the physIQ mobile application (b).
Figure 1. The VitalPatch (a) and display screen showing a participant's electrocardiogram signal on a Samsung Galaxy J3 smartphone running the physIQ mobile application (b).CC BY-NC · PubMed Central
Figure 2. Correlation scatterplots (left) and Bland–Altman plots (right) for (a) heart rate, (b) respiratory rate and (c) temperature comparing biosensor measurements and manual measurements obtained by a research nurse. Horizontal dashed lines in the Bland–Altman plots indicate the mean differences (bias) and shaded areas indicate 95% limits of agreement.
Figure 2. Correlation scatterplots (left) and Bland–Altman plots (right) for (a) heart rate, (b) respiratory rate and (c) temperature comparing biosensor measurements and manual measurements obtained by a research nurse. Horizontal dashed lines in the Bland–Altman plots indicate the mean differences (bias) and shaded areas indicate 95% limits of agreement.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Research works printed but not linked: 4

  1. Chan AM, 2013, Conf Proc IEEE Eng Med Biol Soc, 14, 6115
  2. Ngonzi J, 2017, J Womens Health Gynecol, 1, 1
  3. World Health Organization., 2017, Integrated Management of Childhood Illness chart booklet
  4. Byiringiro JC, 2015, J Hosp Adm, 4, 47

Cited by

See all 40

Metadata

Authors
Garbern, S. C., Mbanjumucyo, G., Umuhoza, C., Sharma, V. K., Mackey, J., Tang, O., Martin, K. D., Twagirumukiza, F. R., Rosman, S. L., McCall, N., Wegerich, S. W., & Levine, A. C.
Affiliations
  • Brown University (US)
  • University of Rwanda (RW)
  • Michigan State University (US)
  • Columbia University (US)
  • Boston Children's Hospital (US)
  • Yale University (US)
  • physIQ, Inc., Chicago, USA
Corresponding author
Garbern, Stephanie C
Venue
DIGITAL HEALTH
Published
2019-01
Volume
5
Pages
2055207619879349-2055207619879349
ISSN
2055-2076 (ISSN-L)
OpenAlex
W2977396413
Cited by
39
References
47
Citations by year
2026: 5 · 2025: 10 · 2024: 5 · 2023: 7 · 2022: 5 · 2021: 5 · 2020: 1
FWCI
0.97
Type
journal article
Language
en
Open access
Licence
  • cc-by-nc
  • journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Digital Health (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Brown Emergency Medicine (701-7909)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
wearable biosensors, continuous vital sign monitoring, sepsis, emergency department patients, heart rate, respiratory rate, body temperature, low- and middle-income countries, pediatric patients, intensive care, device feasibility, measurement accuracy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a wearable biosensor device for vital sign monitoring in septic emergency department patients in Rwanda. https://app.cochat.ai/papers/10.1177/2055207619879349
The paper
Garbern, S. C., Mbanjumucyo, G., Umuhoza, C., Sharma, V. K., Mackey, J., Tang, O., Martin, K. D., Twagirumukiza, F. R., Rosman, S. L., McCall, N., Wegerich, S. W., & Levine, A. C. (2019). Validation of a wearable biosensor device for vital sign monitoring in septic emergency department patients in Rwanda. DIGITAL HEALTH. https://doi.org/10.1177/2055207619879349

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.