Ultrasonic beamforming system for interrogating multiple implantable sensors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, we present an ultrasonic beamforming system capable of interrogating individual implantable sensors via backscatter in a distributed, ultrasound-based recording platform known as Neural Dust [1]. A custom ASIC drives a 7 × 2 PZT transducer array with 3 cycles of 32V square wave with a specific programmable time delay to focus the beam at the 800mm neural dust mote placed 50mm away. The measured acoustic-to-electrical conversion efficiency of the receive mote in water is 0.12% and the overall system delivers 26.3% of the power from the 1.8V power supply to the transducer drive output, consumes 0.75μJ in each transmit phase, and has a 0.5% change in the backscatter per volt applied to the input of the backscatter circuit. Further miniaturization of both the transmit array and the receive mote can pave the way for a wearable, chronic sensing and neuromodulation system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
Self-citation
Cited by
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
“(D) The transceiver board consisted of Opal Kelly FPGA board, application-specific integrated circuit (ASIC) board (Seo et al., 2015; Tang et al., 2015), and the transducer connector board.”
InfluentialSelf-citationPiech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Self-citationWireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Miniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
“This problem could be addressed exploiting beam-forming systems [96], in which an array of Tx transducer is opportunely designed to interrogate several chips.”
BackgroundIbrahim, A., Meng, M., & Kiani, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2812420 · Cited by 83
“can partially mitigate the misalignment issue [55].”
Metadata
- Authors
- Seo, D., Tang, H.-Y., Carmena, J. M., Rabaey, J. M., Alon, E., Boser, B. E., & Maharbiz, M. M.
- Venue
- 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2015-08
- Volume
- 2015
- Pages
- 2673-2676
- OpenAlex
- W2296225679
- Cited by
- 31
- References
- 1
- FWCI
- 16.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic beamforming system for interrogating multiple implantable sensors. https://app.cochat.ai/papers/10.1109/embc.2015.7318942
- The paper
- Seo, D., Tang, H.-Y., Carmena, J. M., Rabaey, J. M., Alon, E., Boser, B. E., & Maharbiz, M. M. (2015). Ultrasonic beamforming system for interrogating multiple implantable sensors. 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). https://doi.org/10.1109/embc.2015.7318942
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.