The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Micro-needle electro-tactile display
Abstract
Haptic feedback is strongly demanded for high-precision robot-assisted surgery and teleoperation. The haptic feedback consists of force and tactile feedback, however tactile feedback has been little studied and the size and weight of the system poses challenges for practical applications. In this paper we propose a sheet-type wearable electro-tactile display which provides tactile sensations to the user as the feedback at a low voltage and power consumption. The display possesses needle-shaped electrodes, which can penetrate through the high-impedance stratum corneum. We developed the fabrication process and, as the first step, we investigated the tactile sensation that can be created to the fingertip by the display. Rough and smooth surfaces were successfully presented to the user. Then, we characterized the tactile display when used on the forearm, in particular, with respect to the spatial resolution. These tactile displays can be used to inform the user of the surface property of the parts of interest, such as tumor tissues, and to guide him in the manipulation of surgery robots.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“but this kind of penetration mode still has the risk of skin lesions and infections (15–18).”
From Self-powered electro-tactile system for virtual tactile experiences (2021) · cites this paper as [16]
In the citing paper
“Previously reported ET devices usually rely on the pulse current transmitted from anode/cathode to ground electrode through the skin, in which two electrodes and the high electric current are indispensable (10, 16).”
From Self-powered electro-tactile system for virtual tactile experiences (2021) · cites this paper as [16]
In the citing paper
“It is possible to lower down voltage and current value for electrostimulation by using needle electrodes to release signal under the epidermis”
From Self-powered electro-tactile system for virtual tactile experiences (2021) · cites this paper as [16]
Citations
Cites
Robotic Surgery: A Current Perspective
Lanfranco, A. R., Castellanos, A. E., Desai, J. P., & Meyers, W. C. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000103020.19595.7d · Cited by 1,299
Haptic feedback in robot-assisted minimally invasive surgery
Okamura, A. M. (2009) · Current Opinion in Urology · doi:10.1097/mou.0b013e32831a478c · Cited by 708
State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery
Puangmali, P., Althoefer, K., Seneviratne, L. D., Murphy, D., & Dasgupta, P. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917481 · Cited by 588
Form perception with a 49-point electrotactile stimulus array on the tongue: a technical note.
Bach‐y‐Rita, P., Kaczmarek, K. A., Tyler, M. E., & Garcia-Lara, J. (1998) · PubMed · Cited by 338
Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery
King, C.-H., Culjat, M. O., Franco, M. L., Lewis, C. E., Dutson, E. P., Grundfest, W. S., & Bisley, J. W. (2009) · IEEE Transactions on Haptics · doi:10.1109/toh.2009.4 · Cited by 224
SmartTouch: electric skin to touch the untouchable
Kajimoto, H., Kawakami, N., Tachi, S., & Inami, M. (2004) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2004.1255807 · Cited by 173
Ju, B.-F., Chen, Y.-L., & Ge, Y. (2011) · Review of Scientific Instruments · doi:10.1063/1.3529880 · Cited by 122
An automated tactile tester for evaluation of cutaneous sensibility
Horch, K., Hardy, M. A., Jimenez, S., & Jabaley, M. E. (1992) · The Journal Of Hand Surgery · doi:10.1016/0363-5023(92)90452-u · Cited by 48
Electrotactile display using microfabricated micro-needle array
Kitamura, N., Chim, J., & Miki, N. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/2/025016 · Cited by 37
Self-citation
Cited by
Self-powered electro-tactile system for virtual tactile experiences
Shi, Y., Wang, F., Tian, J., Li, S., Fu, E., Nie, J., Lei, R., Ding, Y., Chen, X., & Wang, Z. L. (2021) · Science Advances · doi:10.1126/sciadv.abe2943 · Cited by 251
Metadata
- Authors
- Tezuka, M., Kitamura, N., & Miki, N.
- Affiliations
- Keio University (JP)
- ORCID
- Miki, Norihisa
- Venue
- 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2015-08
- Volume
- 2015
- Pages
- 5781-5784
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2294480443
- Cited by
- 7
- References
- 9
- Citations by year
- 2026: 1 · 2024: 2 · 2022: 1 · 2021: 1 · 2017: 1 · 2016: 1
- FWCI
- 1.11
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Precursory Research for Embryonic Science and Technology
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- tactile feedback, robotic surgery, teleoperation, stratum corneum, spatial resolution, surface texture perception
- MeSH terms
- Electrodes, Feedback, Fingers, Humans, Needles, Touch, User-Computer Interface
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.