The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery
Abstract
Robot-assisted minimally invasive surgery has gained widespread use over the past decade, but the technique is currently operated in the absence of haptic feedback during tissue manipulation. We have developed a complete tactile feedback system, consisting of a piezoresistive force sensor, control system, and pneumatic balloon tactile display, and mounted directly onto a da Vinci surgical robotic system. To evaluate the effect of tactile feedback on robotic manipulation, a group of novices (n = 16) and experts ( n = 4) were asked to perform three blocks of peg transfer tasks with the tactile feedback system in place. Force generated at the end-effectors was measured in all three blocks, but tactile feedback was active only during the middle block. All subjects used higher force when the feedback system was inactive. When active, subjects immediately used substantially less force and still maintained appropriate grip during the task. After the system was again turned off, grip force increased significantly to prefeedback levels. These results demonstrate that robotic manipulations without tactile feedback are done with more force than needed to grasp objects. Therefore, the addition of tactile feedback allows the surgeon to grasp with less force, and may improve control of the robotic system and handling of tissues and other objects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Factors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
Cited by
A review of tactile sensing technologies with applications in biomedical engineering
Tiwana, M. I., Redmond, S. J., & Lovell, N. H. (2012) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.02.051 · Cited by 721
Konstantinova, J., Jiang, A., Althoefer, K., Dasgupta, P., & Nanayakkara, T. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2325794 · Cited by 166
Micro-needle electro-tactile display
Tezuka, M., Kitamura, N., & Miki, N. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319706 · Cited by 7
Metadata
- Authors
- King, C.-H., Culjat, M. O., Franco, M. L., Lewis, C. E., Dutson, E. P., Grundfest, W. S., & Bisley, J. W.
- Venue
- IEEE Transactions on Haptics
- Published
- 2009-04
- Volume
- 2
- Issue
- 2
- Pages
- 103-110
- ISSN
- 1939-1412 (ISSN-L)
- OpenAlex
- W2095971486
- Cited by
- 224
- References
- 1
- FWCI
- 23.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery. https://app.cochat.ai/papers/10.1109/toh.2009.4
- The paper
- King, C.-H., Culjat, M. O., Franco, M. L., Lewis, C. E., Dutson, E. P., Grundfest, W. S., & Bisley, J. W. (2009). Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery. IEEE Transactions on Haptics. https://doi.org/10.1109/toh.2009.4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.