Support vector machine classification of Parkinson’s disease and essential tremor subjects based on temporal fluctuation
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Tremor is a common symptom shared in both Parkinson's disease (PD) and Essential tremor (ET) subjects. The differential diagnosis of PD and ET tremor is important since the realization of treatment depends on specific medication. A novel feature is developed based on a hypothesis that tremor of PD subject has a larger fluctuation during resting than action task. Tremor signal is collected using a triaxial gyroscope sensor attached to subject's finger during kinetic and resting task. The angular velocity signal is analyzed by transforming a one-dimensional to two-dimensional signal using a relation of signal and its delay versions. Tremor fluctuation is defined as the area of 95% confidence ellipse covering the two-dimensional signal. The tremor fluctuation during kinetic and resting task is used as classification features. The support vector machine is used as a classifier and tested with 10-fold cross-validation. This novel feature provides a perfect PD/ET classification with 100% accuracy, sensitivity and specificity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Already, some studies have shown that wearable sensors and smartphones can be utilized to distinguish individuals with ET from healthy individuals and people with PD (85–91).”
From Could Wearable and Mobile Technology Improve the Management of Essential Tremor? (2018) · cites this paper as [86]
In the citing paper
“Recent results show an accuracy of 100% in differentiating both disorders (86).”
From Could Wearable and Mobile Technology Improve the Management of Essential Tremor? (2018) · cites this paper as [86]
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Exploring the relationship between essential tremor and Parkinson's disease
Shahed, J., & Jankovic, J. (2007) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2006.05.033 · Cited by 218
Smart watch accelerometry for analysis and diagnosis of tremor
Wile, D. J., Ranawaya, R., & Kiss, Z. H. T. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.04.021 · Cited by 148 · cited 1×
“Features are extracted by some general or specific methods such as peak frequency [5, 8], RMS [6-7], approximate entropy [6-7, 11], power spectral density [8-9, 11], shape of signal distribution [5, 7], wavelet coefficients [9, 11, 13] and higher order statistic parameter [9-10].”
MethodSurface EMG and acceleration signals in Parkinson’s disease: feature extraction and cluster analysis
Rissanen, S. M., Kankaanpaa, M. J., Meigal, A. Y., Tarvainen, M. P., Nuutinen, J., Tarkka, I. M., Airaksinen, O., & Karjalainen, P. A. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0369-0 · Cited by 105
Distinguishing the Central Drive to Tremor in Parkinson’s Disease and Essential Tremor
Brittain, J.-S., Cagnan, H., Mehta, A. R., Saifee, T. A., Edwards, M. J., & Brown, P. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.3768-14.2015 · Cited by 77
The classification of human tremor signals using artificial neural network
Engin, M., Demirağ, S., Engın, E. Z., CELEBI, G., Ersan, F., ASENA, E., & Çolakoğlu, Z. (2006) · Expert Systems with Applications · doi:10.1016/j.eswa.2006.06.014 · Cited by 69
Parkinson’s disease and essential tremor classification on mobile device
Woods, A. M., Nowostawski, M., Franz, E. A., & Purvis, M. (2014) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2013.10.002 · Cited by 69
EMG signal morphology and kinematic parameters in essential tremor and Parkinson’s disease patients
Ruonala, V., Meigal, A. Y., Rissanen, S. M., Airaksinen, O., Kankaanpaa, M. J., & Karjalainen, P. A. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2013.12.007 · Cited by 63
Hossen, A., Muthuraman, M., Raethjen, J., Deuschl, G., & Heute, U. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2010.02.005 · Cited by 57
Classification of normal and pathological tremors using a multidimensional electromagnetic system
Spyers-Ashby, J. M., Stokes, M. J., Bain, P. G., & Roberts, S. J. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00004-7 · Cited by 54
Research works printed but not linked: 1
- vapnik, 1999, The Natural of Statistical Learning Theory
Cited by
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Machine Learning for the Diagnosis of Parkinson's Disease: A Review of Literature
Mei, J., Desrosiers, C., & Frasnelli, J. (2021) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2021.633752 · Cited by 401
Moon, S., Song, H.-J., Sharma, V. D., Lyons, K. E., Pahwa, R., Akinwuntan, A., & Devos, H. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00756-5 · Cited by 152
Vocal Feature Extraction-Based Artificial Intelligent Model for Parkinson’s Disease Detection
Hoq, M., Uddin, M. N., & Park, S.-B. (2021) · Diagnostics · doi:10.3390/diagnostics11061076 · Cited by 102
Lu, R., Xu, Y., Li, X., Fan, Y., Zeng, W., Tan, Y., Ren, K., Chen, W., & Cao, X. (2020) · Parkinson s Disease · doi:10.1155/2020/4693019 · Cited by 94
Moradi, S., Tapak, L., & Afshar, S. (2022) · BioMed Research International · doi:10.1155/2022/5009892 · Cited by 62
Bhidayasiri, R., Sringean, J., Phumphid, S., Anan, C., Thanawattano, C., Deoisres, S., Panyakaew, P., Phokaewvarangkul, O., Maytharakcheep, S., Buranasrikul, V., et al. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1386608 · Cited by 58
Self-citationQuantitative Analysis of Parkinsonian Tremor in a Clinical Setting Using Inertial Measurement Units
Lukšys, D., Jonaitis, G., & Griškevičius, J. (2018) · Parkinson s Disease · doi:10.1155/2018/1683831 · Cited by 54
Duque, J. D. L., Egea, A. J. S., Reeb, T., Rojas, H. A. G., & González‐Vargas, A. M. (2020) · IEEE Access · doi:10.1109/access.2020.2993647 · Cited by 44
Parkinson’s disease severity clustering based on tapping activity on mobile device
Surangsrirat, D., Sri-iesaranusorn, P., Chaiyaroj, A., Vateekul, P., & Bhidayasiri, R. (2022) · Scientific Reports · doi:10.1038/s41598-022-06572-2 · Cited by 42
Self-citationUpper limb intention tremor assessment: opportunities and challenges in wearable technology
Paredes-Acuña, N., Utpadel-Fischler, D., Ding, K., Thakor, N. V., & Cheng, G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01302-9 · Cited by 27
Shin, J., Matsumoto, M., Maniruzzaman, M., Hasan, M. A. M., Hirooka, K., Hagihara, Y., Kotsuki, N., Inomata‐Terada, S., Terao, Y., & Kobayashi, S. (2024) · IEEE Access · doi:10.1109/access.2024.3386367 · Cited by 26
Duque, J. D. L., González‐Vargas, A. M., Egea, A. J. S., & Rojas, H. A. G. (2019) · Communications in computer and information science · doi:10.1007/978-3-030-31019-6_32 · Cited by 24
Li, Z., & Tam, V. W. L. (2017) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci.2017.8285319 · Cited by 24
Could Wearable and Mobile Technology Improve the Management of Essential Tremor?
Daneault, J.-F. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00257 · Cited by 21
Li, J., Zhu, H., Li, J., Wang, H., Wang, B., Luo, W. F., & Pan, Y. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3306203 · Cited by 21
Differentiating essential tremor and Parkinson’s disease using a wearable sensor—a pilot study
Locatelli, P., & Alimonti, D. (2017) · 2017 7th IEEE International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi.2017.7974254 · Cited by 19
Development of a New Wearable Device for the Characterization of Hand Tremor
Vescio, B., Maria, M. D., Crasà, M., Nisticò, R., Calomino, C., Aracri, F., Quattrone, A., & Quattrone, A. (2023) · Bioengineering · doi:10.3390/bioengineering10091025 · Cited by 19
Khalil, R. M., Shulman, L. M., Gruber‐Baldini, A. L., Reich, S. G., Savitt, J. M., Hausdorff, J. M., von Coelln, R., & Cummings, M. P. (2025) · Biomedicines · doi:10.3390/biomedicines13030572 · Cited by 15
A rest tremor detection system based on internet of thing technology
Faizah, S., Nugraha, D. T., Abdulrazaq, M. N., Dionova, . W., Abdullah, M. I., & Novianti, L. (2024) · Indonesian Journal of Electrical Engineering and Computer Science · doi:10.11591/ijeecs.v33.i1.pp476-484 · Cited by 13
Lukman, A., Harjoko, A., & Yang, C.-K. (2017) · International Conference on Soft Computing, Intelligent System and Information Technology (ICSIIT) · doi:10.1109/icsiit.2017.28 · Cited by 13
Valdunciel, A. P., Lopo-Martínez, V., Beltrán-Carrero, A. J., Sendra-Arranz, R., González-Sánchez, M., Sánchez, J. R. P., Grandas, F., Farina, D., Pons, J. L., Barroso, F. O., et al. (2023) · Entropy · doi:10.3390/e25010114 · Cited by 12
Kinetic tremor analysis using wearable sensors and fuzzy inference systems in Parkinson's disease
Fernández, L. P. S., Sánchez-Pérez, L. A., Concha-Gómez, P. D., & Shaout, A. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104748 · Cited by 12
Prospectively Assigned AAST Grade versus Modified Hinchey Class and Acute Diverticulitis Outcomes
Choi, J., Bessoff, K. E., Bromley-Dulfano, R. A., Li, Z., Gupta, A., Taylor, K. K., Wadhwa, H., Seltzer, R. A., Spain, D. A., & Knowlton, L. M. (2020) · Journal of Surgical Research · doi:10.1016/j.jss.2020.10.016 · Cited by 10
Analysis and Implementation of Machine Learning Model for Detection of Parkinson’s Disease
Spandan, K., Kumar, B., Banerjee, P., Jha, P., Pathak, L. K., & Dehury, M. K. (2023) · International Conference on Sustainable Computing and Data Communication Systems (ICSCDS) · doi:10.1109/icscds56580.2023.10104661 · Cited by 9
Cheng, F., Duan, Y., Jiang, H., Zeng, Y., Chen, X., Qin, L., Zhao, L., Yi, F., Tang, Y., & Liu, C. (2022) · BioMedical Engineering OnLine · doi:10.1186/s12938-022-01050-2 · Cited by 9
Hypoglycemia Detection Using Hand Tremors: Home Study of Patients With Type 1 Diabetes
Jahromi, R. K., Zahed, K., Sasangohar, F., Erraguntla, M., Mehta, R. K., & Qaraqe, K. A. (2023) · JMIR Diabetes · doi:10.2196/40990 · Cited by 8
Customer Satisfaction Analysis of Mobile Banking Application Based on Twitter Data
Ligiarta, M. A., & Ruldeviyani, Y. (2022) · International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS) · doi:10.1109/ice3is56585.2022.10010221 · Cited by 8
Machine learning in digital health, recent trends, and ongoing challenges
Cummins, N., Ren, Z. X., Mallol-Ragolta, A., & Schuller, B. W. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817133-2.00005-7 · Cited by 7
Sankineni, S., Saraswat, A., Suchetha, M., Aakur, S. N., Sehastrajit, S., & Dhas, D. E. (2023) · Evolutionary Intelligence · doi:10.1007/s12065-023-00859-7 · Cited by 6
Real-time classification of movement patterns of tremor patients
Piepjohn, P., Bald, C., Kuhlenbäumer, G., Becktepe, J. S., Deuschl, G., & Schmidt, G. (2022) · Biomedical Engineering / Biomedizinische Technik · doi:10.1515/bmt-2021-0140 · Cited by 5
Detection of Tremor Associated with Rest and Effort Activity Using Machine Learning
Aljihmani, L., Kerdjidj, O., Zhu, Y., Mehta, R. K., & Qaraqe, K. A. (2020) · International Conference Automatics and Informatics (ICAI) · doi:10.1109/icai50593.2020.9311368 · Cited by 4
RT-ring: a small wearable device for tremulous Parkinson’s disease diagnosis in primary care
Buonocore, J., Vescio, B., Maria, M. D., Crasà, M., Nisticò, R., Arcuri, P. P., Cascini, G. L., Latorre, A., Quattrone, A., & Quattrone, A. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1534205 · Cited by 3
Gopinath, K. (2019) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2019.3284 · Cited by 3
Higher Prediction Accuracy on Parkinson Disease Patients Using Random Forest Algorithm over DTA
Manoj, S., & Rajendran, T. (2022) · Advances in parallel computing · doi:10.3233/apc220081 · Cited by 3
Exploration of Smart Medical Technology Based on Intelligent Computing Methods
Wang, S., & Jiang, Y. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-84529-2_24 · Cited by 3
Sushkova, O. S., Morozov, A. A., Gabova, A. V., Khokhlova, M., Kershner, I. A., Chigaleichick, L. A., Poleschuk, V. V., & Karabanov, A. V. (2024) · International Conference on Digital Signal Processing and its Applications (DSPA) · doi:10.1109/dspa60853.2024.10510032 · Cited by 2
Tremor Suppression in the Human Hand and Forearm
Hosseini, S. M. (2019) · UTS ePRESS (University of Technology Sydney) · Cited by 2
Locatelli, P. (2021) · Aisberg (University of Bergamo) · doi:10.6092/978-88-97413-37-0 · Cited by 1
Smartwatch-Based IMU Analysis of Motor Tasks for Parkinson's Disease Screening
Suk-ieam, K., Udomkhwamsuk, W., Amornrungrojanakul, N., Lertyongphati, A., Sri-iesaranusorn, P., & Surangsrirat, D. (2025) · International Convention on Rehabilitation Engineering & Assistive Technology · doi:10.1109/i-create67590.2025.11478101 · Cited by 1
Self-citationComparative analysis of decision tree and naive bayes algorithm to predict Parkinson disease
Manoj, S., Shibi, C. S., & Lakshmi, S. V. (2024) · AIP conference proceedings · doi:10.1063/5.0203726 · Cited by 1
Alcohol Withdrawal Syndrome Assessment based on Tremor Time-Frequency Analysis
Norouzi, N. (2017) · TSpace (University of Toronto)
Machine-learning to promote better practices of low-cost wearable devices in tremor diseases
Duque, J. D. L. (2023) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-404064
Khalil, R. M. (2025) · University Libraries (University of Maryland) · doi:10.13016/ustd-0cfo
L’analyse de signaux EMG et leur application au diagnostic de la maladie de Parkinson
Bengacemi, H. (2021) · theses.fr (ABES) · doi:10.70675/c9e9d83azeffez4851zbe06z6e079bd7ee64
Machine Learning for Differentiating Essential Tremor: A Scoping Review
Fletcher, D. R., Heintzelman, K. E., Ramasamy, S. B., Marks, A., Melott, J. C., Amara, A. W., & Memon, A. A. (2026) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.1182
An Intelligent Machine Learning Framework for Early Parkinsonian Symptom Identification
Sankar, S. R., Diya sawant, M., Harini, M., & Abinaya, R. (2026) · International Journal of Engineering & Extended Technologies Research · doi:10.15662/ijeetr.2026.0802091
Tremor Morphology Toolkit: Waveform Modulation-Based Tremor PhenotypingPreprint
Joshi, P. N., Borges, Y., Pandey, S., Vidailhet, M., Fung, V. S. C., Hallett, M., Jinnah, H. A., Fasano, A. A., & Shaikh, A. G. (2026) · medRxiv · doi:10.64898/2026.11.05.26367334
Metadata
- Authors
- Surangsrirat, D., Thanawattano, C., Pongthornseri, R., Dumnin, S., Anan, C., & Bhidayasiri, R.
- Affiliations
- National Electronics and Computer Technology Center (TH)
- Chulalongkorn University (TH)
- Thai Red Cross Society (TH)
- Venue
- 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2016-08
- Volume
- 2016
- Pages
- 6389-6392
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2538067752
- Cited by
- 42
- References
- 18
- Citations by year
- 2025: 3 · 2024: 6 · 2023: 8 · 2022: 6 · 2021: 5 · 2020: 6 · 2019: 1 · 2018: 2 · 2017: 5
- FWCI
- 3.71
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Keywords
- Parkinson's disease, essential tremor, tremor, differential diagnosis, temporal fluctuations, support vector machine, triaxial gyroscope, angular velocity, delay embedding, confidence ellipses, resting tremor, kinetic tremor, feature extraction
- MeSH terms
- Aged, Diagnosis, Differential, Female, Humans, Kinetics, Male, Parkinson Disease, Rest, Signal Processing, Computer-Assisted, Time Factors, Essential Tremor, Support Vector Machine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.