Cited by 34Wireless Power Transfer SystemsWireless Body Area NetworksInduction Heating and Inverter Technology

The DOI matches its Crossref record.

Numerical simulation of Wireless Power Transfer system to recharge the battery of an implanted cardiac pacemaker

Cruciani, Silvano, Campi, Tommaso, Maradei, Francesca, Feliziani, Mauro·2014·2014 International Symposium on Electromagnetic Compatibility

Abstract

This study deals with the design of an inductive Wireless Power Transfer (WPT) system to recharge the battery of a pacemaker. A co-simulation tool is developed using both circuit and electromagnetic field models to simulate all parts of a WPT system for a pacemaker. The pacemaker equipped with the secondary coil of the WPT system is assumed to be implanted in the human body, while the primary coil is placed on the body surface. The eddy currents induced on the titanium case of the pacemaker can alter the WPT performances and therefore the use of magnetic shield placed on the case surface is also proposed. Some numerical results are presented and validated by measurements in simple configurations.

Overview

Integrity signals

Registry

Crossref · 10.1109/emceurope.2014.6930874

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 11

  1. 10.1109/20.668071 · DOI
  2. 10.1109/MEMB.2006.1636350 · DOI
  3. campi, 2014, Magnetic shielding of wireless power transfer systems, 2014 Int Symp on Electromag Compat
  4. 10.1109/11.142666 · DOI
  5. 10.1109/APEMC.2012.6237915 · DOI
  6. 10.1088/0031-9155/41/11/003 · DOI · Paper page
  7. 10.1088/0031-9155/41/11/002 · DOI
  8. 10.1109/IEMBS.2000.897843 · DOI
  9. feliziani, 2011, Magnetic field analysis and lumped inductance extraction for wireless power transfer in implanted medical devices, 2011 Asia-Pacific EMC Symposium
  10. 10.1109/TIE.2003.822038 · DOI
  11. 10.1109/TMAG.2014.2305135 · DOI

Cited by

Sorted by citations

Metadata

Authors
Cruciani, S., Campi, T., Maradei, F., & Feliziani, M.
Affiliations
  • University of L'Aquila (IT)
  • Sapienza University of Rome (IT)
Venue
2014 International Symposium on Electromagnetic Compatibility
Publisher
IEEE
Published
2014-09
Pages
44-47
OpenAlex
W2096752470
Cited by
34
References
0
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2023: 2 · 2022: 4 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 4 · 2016: 2 · 2015: 3
FWCI
3.65
Type
conference paper
Language
en
Open access
closed
Locations
  • Cineca Institutional Research Information System (Tor Vergata University) (submittedVersion)
  • IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
  • Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Induction Heating and Inverter Technology
Keywords
wireless power transfer, cardiac pacemaker, inductive power transfer, biomedical implants, co-simulation, eddy currents, magnetic shielding

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review