Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 217

The DOI matches its Crossref record.

Energy storage system with ultracaps on board of railway vehicles

Steiner, Michael, Klohr, Markus, Pagiela, Stanislaus · 2007 · 2007 European Conference on Power Electronics and Applications

Abstract

The on board energy storage system with Ultracaps for railway vehicles presented in this paper seems to be a reliable technical solution with an enormous energy saving potential. Bombardier Transportation has equipped one bogie of a prototype LRV (light rail vehicle) for the public transportation operator RNV in Mannheim with a MITRAC Energy Saver. Outstanding feature is the daily operation of the energy storage unit in daily passenger service, and this even since September 2003. The experiences are very positive. The measured traction energy saving of approximately 30% confirmed fully the former calculations. Running the energy storage device on board of a tram brings additionally following benefits: (i) a dramatic reduction of the peak power demand (ii) catenary free operation" on several hundred meters without power supply from the catenary (iii) catenary free city center by on board storage and recharging stations. Applying the energy storage devices in Metro systems has a similar effect as in case of LRVs. However the savings distribution in the whole system will be a little bit different. Due to higher regeneration capability of metro systems the expected share of the train propulsion saving will be lower. It will be compensated by a considerable reduction of the line losses, especially for systems with low rated catenary voltages (600 V or 750 V). Very promising are energy storage applications in propulsion systems of diesel-electrical multiple units (DEMUs). These vehicles lack possibilities to use the braking energy of the train. Energy storage systems on board of DEMUs bring high fuel savings together with the corresponding emission reduction. On top of that the energy storage leads to a booster effect - extra power during acceleration from the storage, by adding the limited weight of the MITRAC Energy Saver.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/epe.2007.4417400

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 217

Metadata

Authors
Steiner, M., Klohr, M., & Pagiela, S.
Venue
2007 European Conference on Power Electronics and Applications
Publisher
IEEE
Published
2007
Pages
1-10
OpenAlex
W2534036108
Cited by
217
References
0
FWCI
24.11
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Energy storage system with ultracaps on board of railway vehicles. https://app.cochat.ai/papers/10.1109/epe.2007.4417400
The paper
Steiner, M., Klohr, M., & Pagiela, S. (2007). Energy storage system with ultracaps on board of railway vehicles. 2007 European Conference on Power Electronics and Applications. https://doi.org/10.1109/epe.2007.4417400

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.