Cited by 9Optimal Power Flow DistributionPower System Reliability and MaintenanceElectric Power System Optimization

Stochastic Concept for Modeling Distributed Energy Resources in Power Systems

Bendik, Jozef, Cenky, Matej, Eleschova, Zaneta, Belan, Anton, Cintula, Boris, Janiga, Peter·2022·2022 22nd International Scientific Conference on Electric Power Engineering (EPE)

Abstract

Distributed energy resources have become a stable and rapidly growing part of power systems. DER character and properties depend significantly on the type used technology and application. Their common feature is the probabilistic nature of their behavior and parameters. Penetration of DER into classical power systems raises the question of power quality and operational safety. This paper presents a general method to implement any DER into a custom power system and calculate the probabilities of possible impacts. The proposed method is based on the combination of deterministic, probabilistic, unknown parameters and information about investigating power system and future scenarios of DER penetration. The Paper also presents a case scenario where penetration of PV system into low voltage network is investigated. The last part shows the complex result of probabilistic power flow calculations. Presented methods have been used for practical applications to determine hosting capacity for PV systems in rural and urban areas of the Slovak republic.

Integrity signals

Registry

Crossref · 10.1109/epe54603.2022.9814093

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Increasing PV in LV networks does not always lead to increased conductor currents and TR loading; if the PoC consumes most of the generated power, line and transformer losses decrease.

    “Increasing PV in LV networks does not always lead to increased conductor currents and TR loading.If the PoC is capable of consuming most of the generated power, then the opposite is true, and line and transformer losses decrease [30,47].”

Cited by

Sorted by citations

Authors
Bendik, J., Cenky, M., Eleschova, Z., Belan, A., Cintula, B., & Janiga, P.
Affiliations
  • Institute of Power and Applied Electrical Engineering Slovak University of Technology,Bratislava,Slovakia
  • Slovak University of Technology in Bratislava (SK)
Venue
2022 22nd International Scientific Conference on Electric Power Engineering (EPE)
Publisher
IEEE
Published
2022-06-08
Pages
1-6
OpenAlex
W4284893614
Cited by
9
References
0
Citations by year
2026: 2 · 2024: 2 · 2023: 4 · 2022: 1
FWCI
2.83
Type
conference paper
Language
en
Open access
closed
Locations
International Scientific Conference on Electric Power Engineering (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Power System Reliability and Maintenance
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power System Optimization
Keywords
distributed energy resources, stochastic modeling, probabilistic load flow, photovoltaic systems, low-voltage distribution networks, hosting capacity, power quality, operational safety

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review