The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
AMPds: A public dataset for load disaggregation and eco-feedback research
Abstract
A home-based intelligent energy conservation system needs to know what appliances (or loads) are being used in the home and when they are being used in order to provide intelligent feedback or to make intelligent decisions. This analysis task is known as load disaggregation or non-intrusive load monitoring (NILM). The datasets used for NILM research generally contain real power readings, with the data often being too coarse for more sophisticated analysis algorithms, and often covering too short a time period. We present the Almanac of Minutely Power dataset (AMPds) for load disaggregation research; it contains one year of data that includes 11 measurements at one minute intervals for 21 sub-meters. AMPds also includes natural gas and water consumption data. Finally, we use AMPds to present findings from our own load disaggregation algorithm to show that current, rather than real power, is a more effective measure for NILM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonintrusive appliance load monitoring
Hart, G. W. (1992) · Proceedings of the IEEE · doi:10.1109/5.192069 · Cited by 3,165
The design of eco-feedback technology
Froehlich, J., Findlater, L., & Landay, J. (2010) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753629 · Cited by 813
Nonintrusive appliance load monitoring: Review and outlook
Zeifman, M., & Roth, K. (2011) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2011.5735484 · Cited by 811
Unsupervised Disaggregation of Low Frequency Power Measurements
Kim, H., Marwah, M., Arlitt, M. F., Lyon, G., & Han, J. (2011) · SIAM International Conference on Data Mining · doi:10.1137/1.9781611972818.64 · Cited by 659
Approximate Inference in Additive Factorial HMMs with Application to Energy Disaggregation
Kolter, J. Z., & Jaakkola, T. (2018) · DSpace@MIT (Massachusetts Institute of Technology) · doi:10.1184/r1/6603563 · Cited by 453
Non-Intrusive Load Monitoring Using Prior Models of General Appliance Types
Parson, O., Ghosh, S., Weal, M., & Rogers, A. (2021) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v26i1.8162 · Cited by 354
Energy Disaggregation via Discriminative Sparse Coding
Kolter, J. Z., Batra, S., & Ng, A. Y. (2010) · Cited by 337
On the Accuracy of Appliance IdentificationBased on Distributed Load Metering Data
Reinhardt, A., Baumann, P. R., Burgstahler, D., Hollick, M., Chonov, H., Werner, M., & Steinmetz, R. (2012) · TUbilio (Technical University of Darmstadt) · Cited by 221
Wood, G., & Newborough, M. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.06.009 · Cited by 215
Using appliance signatures for monitoring residential loads at meter panel level
Sultanem, F. (1991) · IEEE Transactions on Power Delivery · doi:10.1109/61.97667 · Cited by 209
Cited by
Kelly, J., & Knottenbelt, W. (2015) · Scientific Data · doi:10.1038/sdata.2015.7 · Cited by 1,086
Yeh, C.-C. M., Zhu, Y., Ulanova, L., Begum, N., Ding, Y., Dau, H. A., Silva, D. F., Mueen, A., & Keogh, E. (2016) · 2016 IEEE 16th International Conference on Data Mining (ICDM) · doi:10.1109/icdm.2016.0179 · Cited by 653
Short-Term Residential Load Forecasting Based on Resident Behaviour Learning
Kong, W., Dong, Z. Y., Hill, D. J., Luo, F., & Xu, Y. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2688178 · Cited by 612
Murray, D., Stankovic, L., & Stankovic, V. (2017) · Scientific Data · doi:10.1038/sdata.2016.122 · Cited by 506
NILMTK: an open source toolkit for non-intrusive load monitoring
Batra, N., Kelly, J., Parson, O., Dutta, H., Knottenbelt, W., Rogers, A., Singh, A., & Srivastava, M. (2014) · Proceedings of the 5th international conference on Future energy systems · doi:10.1145/2602044.2602051 · Cited by 502
Exploiting HMM Sparsity to Perform Online Real-Time Nonintrusive Load Monitoring
Makonin, S., Popowich, F., Bajic, I. V., Gill, B., & Bartram, L. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2494592 · Cited by 378
Self-citationToward Non-Intrusive Load Monitoring via Multi-Label Classification
Tabatabaei, S. M., Dick, S., & Xu, W. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2584581 · Cited by 304
Cominola, A., Giuliani, M., Piga, D., Castelletti, A., & Rizzoli, A. E. (2015) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2015.07.012 · Cited by 304
Electricity, water, and natural gas consumption of a residential house in Canada from 2012 to 2014
Makonin, S., Ellert, B., Bajić, I. V., & Popowich, F. (2016) · Scientific Data · doi:10.1038/sdata.2016.37 · Cited by 296
Self-citationNILM Techniques for Intelligent Home Energy Management and Ambient Assisted Living: A Review
Ruano, A., Hernandez, A., Ureña, J., Ruano, M., & Garcia, J. (2019) · Energies · doi:10.3390/en12112203 · Cited by 271
EXTRACT: Strong Examples from Weakly-Labeled Sensor Data
Blalock, D. W., & Guttag, J. V. (2016) · 2016 IEEE 16th International Conference on Data Mining (ICDM) · doi:10.1109/icdm.2016.0093 · Cited by 7
Metadata
- Authors
- Makonin, S., Popowich, F., Bartram, L., Gill, B., & Bajic, I. V.
- Venue
- 2013 IEEE Electrical Power & Energy Conference
- Publisher
- IEEE
- Published
- 2013-08
- Pages
- 1-6
- OpenAlex
- W2086052667
- Cited by
- 348
- References
- 15
- FWCI
- 34.19
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.