Robust preprocessing for health care monitoring framework
Abstract
Remote health care monitoring is an emerging application that helps to reduce the cost of health care and at the same time improve its quality. However, by its nature, medical sensor data is often unreliable and massive as the data is collected from numerous sensors operating in noisy environments. Therefore, ensuring the reliability of the sensor data and the scalability of the health care monitoring services are among major challenge and is a determining factor in the success of the system. In this paper, we propose a robust and flexible preprocessing module as part of an active health care monitoring framework. It is responsible for preparing the sensor data and performing some initial assessment of the data for input to later modules. The proposed preprocessing architecture contains five stages: validation, transformation, cleaning, reduction and cross-verification. The module is evaluated using synthetic blood pressure data.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Several data mining techniques are applied for these tasks: wavelet analysis for artifact reduction and data compression, rule-based methods for data summarizing and transmitting, and Gaussian process for secure authentication.
“In order to conduct these problems, several data mining techniques are applied such as wavelet analysis for artifact reduction [53] and data compression [54], rule-based methods for data summarizing and transmitting [55,56], and Gaussian process for secure authentication [57].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [56]
Some data analysis systems in healthcare were designed to process short signals such as few minutes of ECG data, a few hours of heart rate or oxygen saturation, and measurement of blood pressures for a day.
“Some data analysis systems in healthcare were designed to process short signals such as few minutes of ECG data [74,92], a few hours of heart rate or oxygen saturation [60,61] and the measurement of blood pressures for a day [56].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [56]
Cites
Hand, D. J., Mannila, H., & Smyth, P. (2001) · Cited by 2,382 · see citing works
Smith, A. E. (2002) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(02)00058-1 · Cited by 1,711 · see citing works
Parsons, S. (2004) · The Knowledge Engineering Review · doi:10.1017/s0269888904220203 · Cited by 521 · see citing works
Declarative Support for Sensor Data Cleaning
Jeffery, S. R., Alonso, G., Franklin, M. J. M., Hong, W., & Widom, J. (2006) · Lecture notes in computer science · doi:10.1007/11748625_6 · Cited by 249 · see citing works
Cleaning and querying noisy sensors
Elnahrawy, E., & Nath, B. (2003) · doi:10.1145/941350.941362 · Cited by 185 · see citing works
Alarms and human behaviour: implications for medical alarms
Edworthy, J. R., & Hellier, E. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael114 · Cited by 185 · see citing works
Are there too many alarms in the intensive care unit? An overview of the problems
Meredith, C., & Edworthy, J. R. (1995) · Journal of Advanced Nursing · doi:10.1046/j.1365-2648.1995.21010015.x · Cited by 137 · see citing works
A Weighted Moving Average-based Approach for Cleaning Sensor Data
Zhuang, Y., Chen, L., Wang, X. S., et al. (2007) · International Conference on Distributed Computing Systems · doi:10.1109/icdcs.2007.83 · Cited by 123 · see citing works
Preprocessing in a Tiered Sensor Network for Habitat Monitoring
Wang, H., Estrin, D. L., & Girod, L. (2003) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/s1110865703212087 · Cited by 104 · see citing works
Cleaning and querying noisy sensors
Elnahrawy, E., & Nath, B. (2003) · doi:10.1145/941360.941362 · Cited by 67 · see citing works
Declarative Support for Sensor Data Cleaning
Shawn, R. J., Alonso, G., Michael, J. F., Hong, W., & Widom, J. (2006) · Lecture notes in computer science · Cited by 61 · see citing works
In-network Outlier Cleaning for Data Collection in Sensor Networks.
Zhuang, Y., & Chen, L. (2006) · Cited by 59 · see citing works
Cardiac health diagnosis using data fusion of cardiovascular and haemodynamic signals
Kannathal, N., Acharya, U. R., Ng, E. Y. K., Krishnan, S. M., Min, L. C., & Laxminarayan, S. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.01.009 · Cited by 35 · see citing works
A Neuro-fuzzy Approach for Sensor Network Data Cleaning
Petrosino, A., & Staiano, A. (2007) · Springer eBooks · doi:10.1007/978-3-540-74829-8_18 · Cited by 16 · see citing works
Sensor Validation within a Pervasive Medical Environment
O’Donoghue, J., Herbert, J., Fensli, R. W., et al. (2006) · doi:10.1109/icsens.2007.355786 · Cited by 15 · see citing works
Data fusion of electrophysiological and haemodynamic signals for ventricular rhythm tracking
Thoraval, L., Carrault, G., Schleich, J.-M., et al. (1997) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.637117 · Cited by 13 · see citing works
DATA ACQUISITION, INTERFACING AND PRE-PROCESSING OF HIGHWAY TRAFFIC DATA
Bellemans, T., Schutter, B. D., & Moor, B. J. D. (2000) · Cited by 7 · see citing works
Power- and delay-aware mobile application-data flow adaptation: the MobiHealth system case study
Wac, K., Bargh, M. S., Peddemors, A., Pawar, P. A., van Beijnum, B.-J. F., & Bults, R. G. A. (2008) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/health.2008.4600138 · Cited by 7 · see citing works
Capturing, Analysing, and Managing ECG Sensor Data in Handheld Devices
Rodríguez, J., Goñi, A., & Illarramendi, A. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39964-3_73 · Cited by 6 · see citing works
Assistive health care monitoring framework using active database approach
Ahmad, N., & Hoang, D. (2009) · UTS ePRESS (University of Technology Sydney) · Cited by 6 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Banaee, H., Ahmed, M., & Loutfi, A. (2013) · Sensors · doi:10.3390/s131217472 · Cited by 452 · see citing works
Sensor data quality: a systematic review
Teh, H. Y., Kempa-Liehr, A. W., & Wang, K. I.-K. (2020) · Journal of Big Data · doi:10.1186/s40537-020-0285-1 · Cited by 377 · see citing works
- Authors
- Ahmad, N. F., Hoang, D. B., & Phung, M. H.
- Affiliations
- University of Technology Sydney (AU)
- ORCID
- Hoang, Doan B.
- Venue
- 2009 11th International Conference on e-Health Networking, Applications and Services (Healthcom)
- Publisher
- IEEE
- Published
- 2009-12
- Pages
- 169-174
- OpenAlex
- W2144263768
- Cited by
- 21
- References
- 20
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 3 · 2021: 1 · 2020: 1 · 2018: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 3 · 2012: 3
- FWCI
- 1.35
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) (publishedVersion)
- OPUS - Open Publications of UTS Scholars (University of Technology Sydney) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Networks and Communications › Wireless Sensor Networks for Data Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- medical sensor data, data preprocessing, sensor data reliability, data cleaning, data validation, data transformation, data reduction, cross-checking, noisy sensor data
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review