The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Hijacking an insulin pump: Security attacks and defenses for a diabetes therapy system
Abstract
Wearable and implantable medical devices are being increasingly deployed to improve diagnosis, monitoring, and therapy for a range of medical conditions. Unlike other classes of electronics and computing systems, security attacks on these devices have extreme consequences and must, therefore, be analyzed and prevented with utmost effort. Yet, very little work exists on this important topic and the security vulnerabilities of such systems are not well understood. We demonstrate security attacks that we have implemented in the laboratory on a popular glucose monitoring and insulin delivery system available on the market, and also propose defenses against such attacks. Continuous glucose monitoring and insulin delivery systems are becoming increasingly popular among patients with diabetes. These systems utilize wireless communication links, which are frequently utilized as a portal to launch security attacks. Our study shows that both passive attacks (eavesdropping of the wireless communication) and active attacks (impersonation and control of the medical devices to alter the intended therapy) can be successfully launched using public-domain information and widely available off-the-shelf hardware. The proposed attacks can compromise both the privacy and safety of patients. We propose two possible defenses against such attacks. One is based on rolling-code cryptographic protocols, and the other is based on body-coupled communication. Our security analysis shows that the proposed defenses have the potential to mitigate the security risks associated with personal healthcare systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An investigation of the Therac-25 accidents
Leveson, N. G., & Turner, C. S. (1993) · Computer · doi:10.1109/mc.1993.274940 · Cited by 1,238
Pacemakers and Implantable Cardiac Defibrillators: Software Radio Attacks and Zero-Power Defenses
Halperin, D., Heydt-Benjamin, T. S., Ransford, B., Clark, S. S., Defend, B., Morgan, W., Fu, K., Kohno, T., & Maisel, W. H. (2008) · 2008 IEEE Symposium on Security and Privacy (sp 2008) · doi:10.1109/sp.2008.31 · Cited by 743
Security and Privacy for Implantable Medical Devices
Halperin, D., Heydt-Benjamin, T. S., Fu, K., Kohno, T., & Maisel, W. H. (2008) · IEEE Pervasive Computing · doi:10.1109/mprv.2008.16 · Cited by 470
The Human Body Characteristics as a Signal Transmission Medium for Intrabody Communication
Cho, N., Yoo, J., Song, S.-J., Lee, J., Jeon, S., & Yoo, H.-J. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895640 · Cited by 355
Proximity-based access control for implantable medical devices
Rasmussen, K. B., Castelluccia, C., Heydt-Benjamin, T. S., & Capkun, S. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653712 · Cited by 229
Human-centric connectivity enabled by body-coupled communications
Baldus, H., Corroy, S., Fazzi, A., Klabunde, K., & Schenk, T. C. W. (2009) · IEEE Communications Magazine · doi:10.1109/mcom.2009.5116816 · Cited by 108
Requirements and design spaces of mobile medical care
Kulkarni, P., & Öztürk, Y. (2007) · ACM SIGMOBILE Mobile Computing and Communications Review · doi:10.1145/1317425.1317427 · Cited by 93
Interoperability and Security in Wireless Body Area Network Infrastructures
Warren, S., Lebak, J. W., Yao, J., Creekmore, J., Milenković, A., & Jovanov, E. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615297 · Cited by 90
Alrabady, A. I., & Mahmud, S. M. (2005) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2004.838829 · Cited by 85
Security for Pervasive Medical Sensor Networks
García-Morchón, Ó., Falck, T., Heer, T., & Wehrle, K. (2009) · EAI International Conference on Mobile and Ubiquitous Systems: Computing, Networking and Services (MobiQuitous) · doi:10.4108/icst.mobiquitous2009.6832 · Cited by 50
Cited by
A Survey on Security and Privacy Issues in Internet-of-Things
Yang, Y., Wu, L., Yin, G., Li, L., & Zhao, H. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2694844 · Cited by 1,278
Cyber-Physical Systems Security—A Survey
Humayed, A., Lin, J., Li, F., & Luo, B. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2703172 · Cited by 1,185
A Survey of Wearable Devices and Challenges
Seneviratne, S., Hu, Y., Nguyen, T., Lan, G., Khalifa, S., Thilakarathna, K., Hassan, M., & Seneviratne, A. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2731979 · Cited by 821
Sundaravadivel, P., Kougianos, E., Mohanty, S. P., & Ganapathiraju, M. K. (2018) · IEEE Consumer Electronics Magazine · doi:10.1109/mce.2017.2755378 · Cited by 305
Security and privacy issues in implantable medical devices: A comprehensive survey
Camara, C., Peris-Lopez, P., & Tapiador, J. E. (2015) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.04.007 · Cited by 293
Metadata
- Authors
- Li, C., Raghunathan, A., & Jha, N. K.
- Venue
- 2011 IEEE 13th International Conference on e-Health Networking, Applications and Services
- Publisher
- IEEE
- Published
- 2011-06
- Pages
- 150-156
- OpenAlex
- W2145548455
- Cited by
- 324
- References
- 17
- FWCI
- 33.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hijacking an insulin pump: Security attacks and defenses for a diabetes therapy system. https://app.cochat.ai/papers/10.1109/health.2011.6026732
- The paper
- Li, C., Raghunathan, A., & Jha, N. K. (2011). Hijacking an insulin pump: Security attacks and defenses for a diabetes therapy system. 2011 IEEE 13th International Conference on e-Health Networking, Applications and Services. https://doi.org/10.1109/health.2011.6026732
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.