The DOI matches its Crossref record.
Proximity-based access control for implantable medical devices
Abstract
We propose a proximity-based access control scheme for implantable medical devices (IMDs). Our scheme is based on ultrasonic distance-bounding and enables an implanted medical device to grant access to its resources only to those devices that are in its close proximity. We demonstrate the feasibility of our approach through tests in an emulated patient environment. We show that, although implanted, IMDs can successfully verify the proximity of other devices with high accuracy. We propose a set of protocols that support our scheme, analyze their security in detail and discuss possible extensions. We make new observations about the security of implementations of ultrasonic distance-bounding protocols. Finally, we discuss the integration of our scheme with existing IMD devices and with their existing security measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Survey on Security and Privacy Issues in Internet-of-Things
Yang, Y., Wu, L., Yin, G., Li, L., & Zhao, H. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2694844 · Cited by 1,278
A secure system for pervasive social network-based healthcare
Zhang, J., Xue, N., & Huang, X. (2016) · IEEE Access · doi:10.1109/access.2016.2645904 · Cited by 361
Hijacking an insulin pump: Security attacks and defenses for a diabetes therapy system
Li, C., Raghunathan, A., & Jha, N. K. (2011) · 2011 IEEE 13th International Conference on e-Health Networking, Applications and Services · doi:10.1109/health.2011.6026732 · Cited by 324
Security and privacy issues in implantable medical devices: A comprehensive survey
Camara, C., Peris-Lopez, P., & Tapiador, J. E. (2015) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.04.007 · Cited by 293
Ghost Talk: Mitigating EMI Signal Injection Attacks against Analog Sensors
Kune, D. F., Backes, J., Clark, S. S., Kramer, D., Reynolds, M., Fu, K., Kim, Y., & Xu, W. (2013) · 2013 IEEE Symposium on Security and Privacy · doi:10.1109/sp.2013.20 · Cited by 275
Metadata
- Authors
- Rasmussen, K. B., Castelluccia, C., Heydt-Benjamin, T. S., & Capkun, S.
- Venue
- Proceedings of the 16th ACM conference on Computer and communications security
- Publisher
- ACM
- Published
- 2009-11-09
- Pages
- 410-419
- ISSN
- 1543-7221 (ISSN-L)
- OpenAlex
- W2101188359
- Cited by
- 229
- References
- 0
- FWCI
- 8.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proximity-based access control for implantable medical devices. https://app.cochat.ai/papers/10.1145/1653662.1653712
- The paper
- Rasmussen, K. B., Castelluccia, C., Heydt-Benjamin, T. S., & Capkun, S. (2009). Proximity-based access control for implantable medical devices. Proceedings of the 16th ACM conference on Computer and communications security. https://doi.org/10.1145/1653662.1653712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.