The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
A Neural Network-based method for continuous blood pressure estimation from a PPG signal
Abstract
There is a relation, not always linear, between the blood pressure and the pulse duration, obtained from photoplethysmography (PPG) signal. In order to estimate the blood pressure from the PPG signal, in this paper the Artificial Neural Networks (ANNs) are used. Training data were extracted from the Multiparameter Intelligent Monitoring in Intensive Care waveform database for better representation of possible pulse and pressure variation. In total there were analyzed more than 15000 heartbeats and 21 parameters were extracted from each of them that define the input vector for the ANN. The comparison between estimated and reference values shows better accuracy than the linear regression method and satisfy the American National Standards of the Association for the Advancement of Medical Instrumentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Teng, X. F., & Zhang, Y. T. (2004) · Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439) · doi:10.1109/iembs.2003.1280811 · Cited by 237
Cattivelli, F. S., & Garudadri, H. (2009) · 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.35 · Cited by 166
Fortino, G., & Giampa, V. (2010) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2010.5480201 · Cited by 128
McCombie, D. B., Reisner, A. T., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260590 · Cited by 118
Using The Morphology of Photoplethysmogram Peaks to Detect Changes in Posture
Linder, S. P., Wendelken, S., Wei, E., & McGrath, S. P. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9015-2 · Cited by 58
Kim, J. Y., Cho, B. H., Im, S. M., Jeon, M.-J., Kim, I. Y., & Kim, S. I. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616102 · Cited by 45
Reliable pulse rate evaluation by smartphone
Lamonaca, F., Kurylyak, Y., Grimaldi, D., & Spagnuolo, V. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226672 · Cited by 41
Self-citationContinuous blood pressure monitoring using pulse wave delay
Meigas, K., Kattai, R., & Lass, J. (2005) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019495 · Cited by 38
Barbé, K., Moer, W. V., & Schoors, D. F. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2161933 · Cited by 35
Cited by
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network
Slapničar, G., Mlakar, N., & Luštrek, M. (2019) · Sensors · doi:10.3390/s19153420 · Cited by 387
El-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101870 · Cited by 294
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Metadata
- Authors
- Kurylyak, Y., Lamonaca, F., & Grimaldi, D.
- Venue
- 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
- Publisher
- IEEE
- Published
- 2013-05
- Pages
- 280-283
- ISSN
- 2642-2069 (ISSN-L)
- OpenAlex
- W2088204643
- Cited by
- 291
- References
- 16
- FWCI
- 11.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.